6
3 Service Navigation
3.1.
Introduction
This service manual contains technical information, which allow service personnel’s to understand and service this model.
Please place orders using the parts list and not the drawing reference numbers.
If the circuit is changed or modified, the information will be followed by service manual to be controlled with original service manual.
3.2.
About service of bundled lenses
Please refer to the following service manuals about Disassembly and Assembly or Maintenance of bundled lenses.
• H-FS12060E/GK/PP: Order No.DSC1604008CE
• H-ES12060PP/E/GK: Order No.DSC1702007CE
3.3.
Important Notice
*When servicing, it is recommended dealing with Clean box. (Refer to “8.2. Clean Box” section of this service manual for details.)
3.3.1.
Camera Body Unit
3.3.1.1.
About Flange back adjustment
* “Flange back” is the distance from the lens mount level to the Image Sensor level.
When turning the image sensor unit mounting screw even a little or removing, the “simplicity flange back adjustment” is need.
Perform the “simplicity flange back adjustment” according to contents described in “10 Measurements and Adjustments” section of
this service manual.
3.3.1.2.
About Shutter Unit (Ref. 5)
Before exchanging the “shutter unit”, confirm that the symptom and/or phenomenon is not due to the setting of functions.
Important:
After replacing the shutter unit, the shutter unit data has to be stored to the unit.
The shutter unit supplied as service parts has affix the label of own configure data.
By inputting second line to third line of these data into the adjustment software and writing these data to Flash-ROM (IP2001),
the shutter adjustment becomes needless.
In addition, the adjustment software can read data encoded to QR Code by using WEB camera with a close-up function.
Refer to the adjustment instruction in the adjustment software for details.
Summary of Contents for LUMIX DC-G9P
Page 18: ...18 ...
Page 19: ...19 ...
Page 20: ...20 ...
Page 21: ...21 ...
Page 22: ...22 4 2 Lens ...
Page 30: ...30 ...
Page 31: ...31 ...
Page 34: ...34 ...
Page 38: ...38 9 1 2 P C B Location ...
Page 41: ...41 Fig D2 Fig D3 ...
Page 42: ...42 Fig D4 Fig D5 ...
Page 43: ...43 Fig D6 Fig D7 9 1 3 2 Removal of the Top Unit Fig D8 ...
Page 44: ...44 Fig D9 Fig D10 ...
Page 45: ...45 Fig D11 9 1 3 3 Removal of the Main P C B Fig D12 ...