161
6-1-8 Timing chart
Position correction - Marking (when TIMING IN signal is used)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T1
T1
T6
T2
T3
T5
T4
TRIGGER IN (X5)
PROCESSING OUT (Y10)
PROCESSING END OUT (Y11)
SCRIPTING OUT (No.37)
TIMING IN (No.24)
TIMING WAIT OUT (No.36)
READY OUT (Y5)
Starting location detection signal
Marking trigger
LASING OUT (No.40)
Item
Time
Remarks
T1
2ms or more
Keep the ON status for 2ms or more.
T2
―
Processing time of linkage operations with the image checker.
In this case, it is the following time.
• Time for location detection by image checker
• Time for marking position correction by the laser marker
T3
―
When TRIGGER IN (X5) is accepted, PROCESSING OUT (Y10) turns ON.
The output time of PROCESSING OUT includes the trigger delay time, operation time,
laser radiation time and laser marker internal processing time of the linkage devices.
T4
Max. 60 sec
Turn on TIMING IN within 60 seconds after TIMING WAIT OUT is turned ON.
If there is no input of TIMING IN within 60 seconds, an error occurs and trigger processing
is terminated due to the abnormality.
T5
―
Laser radiation time. This varies depending on marking contents.
T6
2 to 510 ms
One-shot output. Set the output time on the system settings screen.
There is a small margin of error for the setting value.
ME-LPRH-SM-3
Summary of Contents for LP-RH Series
Page 19: ...1 Product Overview ME LPRH SM 3...
Page 42: ...2 Laser Marker Installation ME LPRH SM 3...
Page 68: ...3 Operation Method ME LPRH SM 3...
Page 90: ...4 External Control Using I O ME LPRH SM 3...
Page 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Page 147: ...6 Link Control with External Devices ME LPRH SM 3...
Page 172: ...7 Maintenance ME LPRH SM 3...
Page 201: ...Troubleshooting ME LPRH SM 3...
Page 236: ...Index ME LPRH SM 3...
Page 239: ......