140
5-2 RS-232C
To control the laser marker by communication commands, use RS-232C or Ethernet connection.
For the control by communication commands, configure the communication settings in advance at the system settings of
Laser Marker NAVI smart. Refer to “3-4-3 General settings before external control” (P.86).
ンㄆㄇㄆㄓㄆㄏㄆ
• The laser marker can be controlled by I/O and communication commands combined.
• For communication commands, refer to “Serial Communication Command Guide”.
5-2-1 Interface specifications and connection
To execute command communication control with RS-232C, connect the RS-232C port on the controller to the external
control device.
5
9
1
6
RS-232C port
(female)
On the laser marker
controller side
Rear of controller
Connector position
Connector specifications
Model
Manufacturer name
On the laser marker
side
D-sub 9-pin, female
Screw type: No.4-40UNC inch screw, female
-
-
User side
D-sub 9-pin, male
Screw type: No.4-40UNC inch screw, male
Recommended connector
XM3A-0921
OMRON
Corporation
Recommended connector cover
XM2S-0913
ME-LPRH-SM-3