31
8. Frame ground terminal: F.G.
This is the terminal for ground. If you use a shielded wire for the I/O terminal block and the I/O connector cable, you
can connect the shielded wire to this terminal.
9. AC power supply terminal: AC INPUT
Terminal for connecting AC power supply. Connect the attached AC power cable.
90V to 132V AC or 180V to 264V AC (inc/-10% voltage fluctuations), 50/60Hz (voltage and frequency are
switched automatically)
ワㄐㄕㄊㄆ
• Be sure to connect the ground pin of the AC power cable to earth permanently. Refer to “2-5-2 Power connection
and earth (Grounding)” (P.42).
10. Fuse holder: FUSE 250V T 10A
Rotate and remove holder for replacing the fuse on fusing.
For details, refer to “7-2-10 Replacement of fuse” (P.157).
11. Protective conductor terminal
This is the terminal for ground. Ground this terminal to the earth permanently.
12. Clamp
This is the clamp for fixing the AC power cable.
13. Controller air-cooling fan (outlet)
The air-cooling fan for the controller.