157
7-2-10 Replacement of fuse
Replace fuse of the controller when blowing.
The power of the laser marker cannot be turned on if the fuse is blown.
Models of replacement parts
Be sure to use the following type of fuse: If the user applies any other fuses than the specified one, failure might result.
Type
Model
Time Lag Fuse (Rating 250V 10A)
0215010
(made by Littelfuse)
Steps for replacement
1.
Remove causes for fuse blowing.
2.
Turn OFF the key switch of the controller, and disconnect the AC power cable.
3.
Turn the fuse holder on the back side, and remove the
fuse.
4.
Replace it with new one.
5.
Turn the fuse holder, and install the fuse.
7-2-11 Replacement of cable
If the cable connecting the head and controller is broken because of the usage conditions and installation environment, it
needs to be replaced.
Models of replacement parts
For details of purchasing cables, contact our sales office.
Part name
Model
Unit power cable
LP-ACP10-5
Signal cable
LP-ACS10-5
Steps for replacement
See “2-5-1 Connection of head and controller” (P.41), and connect cables.
Fuse holder
Rear of controller
ME-LPGS-SM-8
Summary of Contents for LP-GS Series
Page 17: ...1 Product Overview ME LPGS SM 8 ...
Page 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Page 48: ...3 Operation Method ME LPGS SM 8 ...
Page 68: ...4 External Control Using I O ME LPGS SM 8 ...
Page 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Page 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Page 141: ...7 Maintenance ME LPGS SM 8 ...
Page 161: ...161 MEMO ME LPGS SM 8 ...
Page 162: ...Troubleshooting ME LPGS SM 8 ...
Page 186: ...Index ME LPGS SM 8 ...
Page 189: ......
Page 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...