7. DIP Switch
Sets the operational options of the laser marker.
For details, refer to “1-6-3 DIP Switch” (P.57).
Notice
•
A plastic cover is installed on the DIP switch. Install this cover always to avoid the dust penetration to the controller.
8. I/O Connector: I/O
This is the terminal for connecting signal for the purpose of controlling laser marker from the external device.
Refer to External Control Manual for details.
9. Terminal Block Connector: TERMINAL
This is the connector of the terminal for connecting I/O signals to control laser marker from the external device. It is
available to connect the attached terminal.
Refer to External Control Manual for details.
10. AC Power Inlet
Inlet for connecting AC power supply cable. Connect the attached controller power cable.
90V to 132V AC or 180V to 264V AC (including ±10% voltage fluctuations), 50Hz/60Hz (The voltage and frequency
switch automatically.)
Be sure to connect the ground pin of the controller power cable to earth permanently.
11. Frame Ground Terminal: F.G.
This is the terminal for ground. Be sure to connect it to earth permanently.
12. Fuse Holder: FUSE
Rotate and remove holder for replacing the fuse on fusing. The rated ampere of the fuse varies with models.
Refer to “Replacement of fuse” (P.286) for details.
13. Signal Connector: SIGNAL
This is the terminal for communicating between head and controller. Connect the attached head control cable.
14. Power Connector: POWER
This is the connector for supplying the power to the head. Connect the attached head power cable.
15. Cooling Fan of the Controller (Exhaust port)
This is a cooling fan to release the heat from controller part.
16. Fiber Cable [Only for LP-V/LP-W series]
This is the cable for transmitting the laser light. This cable cannot be detached from the device.
ME-LP400V-OP-6
Summary of Contents for LP-400 Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...