52
2-4-9 Rank/Offset marking
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T1
T1
T6
T2
T4
T5
T2
T2
T3
T3
T3
T2
T2
T2
T7
*1
*1
*1
SET IN
SET OK OUT
READY OUT
MARKING OUT
D0 to D15 IN *2
TRIG. IN
SELECT 0 to 2 IN
Data A
Data A
Data B
Data B
Data C
Data C
Item
Time
Remarks
T1
―
Period for creating marking data. It varies depending on the quantity of data to be
marked.
T2
0ms or more
Keep the input until the SET OK is turned to ON.
T3
2 to 510ms
One-shot output. Set the output time on the environment setting screen. There is a
margin for the setting value.
T4
―
When T5 < T1: T4 = T1 - T5
When T5 > T1: T4 is 1ms or less.
T6
0ms or more
Turn ON the SET after MARKING is turned to ON.
T7
0.5ms or more
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN and D0 IN
to D15 IN, turn on SET IN.
*1 : Input SELECT 0 to 2 as the table below.
Number input target
SELECT 0 (No. 20)
SELECT 1 (No. 21)
SELECT 2 (No. 22)
Data No. of rank/external offset
ON
OFF
OFF
*2 : Specify the data number of rank/external offset function by using D0 to D15. Refer to “Operation of input signal on I/O
Reference
•
Input SET IN for the rank/offset data when the laser pumping is completed, and the internal shutter opens.
•
When the rank/external offset function is used, READY will not be output until the data number and SET IN are input.
•
Enter the data number input and SET IN every time for each marking trigger even there is no change to the marking
data.
•
Close the shutter if you want to reset the data number already set.
•
Do not input SET IN for the next data until MARKING output turns on by inputting the marking trigger after inputting SET
IN.
• READY will be output even when the marking data is not configured to the data number input.
• If the rank or external offset functions are used with the marking to the flying object, make sure that the marking interval
time is enough to the required period to input the marking data and to confirm the marking ready output.
ME-LP400V-EX-6
Summary of Contents for LP-400 Series
Page 12: ...1 Before External Control ME LP400V EX 6...
Page 24: ...2 Control by I O ME LP400V EX 6...
Page 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Page 141: ...Troubleshooting ME LP400V EX 6...
Page 158: ...Character Code Table ME LP400V EX 6...
Page 176: ...Index ME LP400V EX 6...
Page 179: ...No 9000 0062 17V...
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...