LIQI
Page 11
Pr4.37
Range
Default
Unit
0 – 10000
0
1ms
Pr4.38
Range
Default
Unit
0 – 10000
0
1ms
Pr4.39 Brake release speed setup
Range
Default
Unit
30 – 3000
30
r/min
Pr4.40 Warning output 1 selection
Range
Default
Unit
0 – 11
0
-
Pr4.41 Warning output 2 selection
Range
Default
Unit
0 – 11
0
-
Alarm
Content
[0]
---
1
Overload protection
Load factor is 85% or more the protection level.
2
Over-regeneration alarm
3
Battery alarm
Battery voltage is 3.2V or lower.
4
Fan alarm
Fan has stopped for 1 sec.
5
6
Encoder overheat alarm
The encoder detects overheat alarm.
7
Oscillation detection alarm Oscillation or vibration is detected.
8
Lifetime detection alarm
Life expectancy of capacitor or fan become short.
9
Pr4.42
Range
Default
Unit
0 – 262144
10
-
* for more detail please refer Panasonic A5 manual
Mechanical brake action at stalling
setup
Mechanical brake action at running
setup
Setup
Value
Ored of all alarms.
Regenerative factor is 85% or more the protection
level.
Encoder communication
Alarm
The number of successive encoder communication
errors exceeds the specified value.
2
nd
in position range