Connections
19
When selecting Ethernet cables (not included)
• Use flexible, high-quality, snagless (without strain relief) cables. Do
not use cables with coating that may tear or crack when bent.
To prevent damage to the cables, use cables that do not protrude from
the bottom of the base.
Connect the cables as shown in the following illustration.
Ethernet cable
Ethernet cable
Incorrect
Correct
60 mm
(2
3/8
in) or less
• Use a straight CAT 5 (or higher) Ethernet cable (not included) that is
6.5 mm (
1
/
4
in) in diameter or less.
When connecting to a switching hub
• If PoE is available, an AC adaptor is not needed.
• This unit complies with the PoE Class 2 standard.
When connecting a PC
• Only a PC can be connected to the PC port. Other SIP phones,
or network devices such as routers or switching hubs, cannot be
connected.
• The PC port does not support PoE for connected devices.
• In cases where a PC is connected to the PC port, if the connection to
the SIP server is disconnected or reset, LAN communication to the PC
will also be disrupted.
• Generally, it is recommended that you connect no more than one PC
to the PC port of each unit.
When connecting cables and the AC adaptor
• Ensure that the Ethernet cables and the AC adaptor cord are clamped
to prevent damage to the connectors.
Summary of Contents for KX-UT113
Page 9: ...Location of Controls 9 For KX UT133 F E B CD KLM NOP QR H G I J A...
Page 13: ...Location of Controls 13 Bottom View For KX UT133 KX UT136 C D B A For KX UT123 A C D B...
Page 20: ...Notes 20...
Page 29: ...Emplacement des commandes 29 Pour le KX UT133 F E B CD KLM NOP QR H G I J A...
Page 40: ...Panasonic System Networks Co Ltd 2011 PNQX3558YA VB DD0511MK1061...