58
KX-TGD320ALB/KX-TGD322ALB/KX-TGD323ALB/KZ-TGDA30AZB
11.6.1.2. Handset
First, operate the PC setting according to
Then download the appropriate data according to the following procedures.
Note:
(*2) WW: country code, XXX_YYY: revision number
“XXX_YYY” vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in
Items
How to download/Required adjustment
FLASH(IC4)
Adjusted parameter data is
stored in memory.
(country version batch file,
default batch file,ect)
1) Please be sure to execute the following steps if you have replaced the FLASH
IC(IC4).
1. Update BBIC. Refer How to update the BBIC.
2. Detach the JIG cable, then disconnect the battery.
3. Insert battery.
4. Connect the JIG cable again, and execute the command "getchk", then con-
firm the checksum value is correct.
• If the downloading failes, start again from step 1.
5. Check DECT ID written on Plastic bag of FLASH (IC4).
6. Execute the command "idw xx xx xx xx xx". xx xx xx xx xx: use DECT ID in
Step 5.
7. Execute the command "epw 00 01 01 AA".
8. Default bath file: Execute the command "default.bat"
9. Common batch file: Execute the command
"TGDA30_EX_DEF_RevXXX_YYY.bat" (*2).
10. Country version batch file: Execute the command
"TGDA30_EX_WW_RevXXX_YYY.bat” (*2).
11. Confirm DECT ID written in the label pated plastic bag of FLASH rom.
12. Write ID(PFPI): Write DECT ID.
• Execute the command "IDWRITE". Refer to
2) Clock adjustment.
3) Battery low confirmation as below.
Battery Low Confirmation
-
1) Apply 2.40 V between BATT+ and BATT-.
2) Confirm that there is no flashing of Battery lcon.
3) Apply 2.25 V ± 0.08 V between BATT+ and BATT-.
4) Confirm that there is flashing of Battery lcon.
If need to adjust Battery low detection, please proceed as below.
5) Apply 2.25V between BATT+ and BATT-
Execute the command
sendchar PAD
sendchar LED 0
sendchar CRX 0 1
sendchar AD1
It assumes that the return value is XX*.
a) 6c XX 71: No need to adjust
b) XX: 6A ~ 6B: Need to adjust
Execute the command
wreeprom 00 09 01 XX
wreeprom 00 0A 01 ZZ
ZZ = XX-1D (hex)
Note:
* : If XX is “00” to “69” or “75” to “FF” it may not be able to adjust properly.
Please check power circuit.
Clock Adjustment (X1)
CLK
1) Apply 2.6 V between BATT+ and BATT- with DC power.
2) Input Command “sendchar sfr“, then you can confirm the current value.
3) Check X’tal Frequency. (10.368 MHz ± 100 Hz).
4) If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CLK
execute in the command “sendchar sfr xx xx (where xx is the value)“ so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
Summary of Contents for KX-TGD320ALB
Page 69: ...69 KX TGD320ALB KX TGD322ALB KX TGD323ALB KX TGDA30AZB Memo ...
Page 73: ...73 KX TGD320ALB KX TGD322ALB KX TGD323ALB KX TGDA30AZB Memo ...
Page 76: ...76 KX TGD320ALB KX TGD322ALB KX TGD323ALB KZ TGDA30AZB Memo ...
Page 80: ...80 KX TGD320ALB KX TGD322ALB KX TGD323ALB KZ TGDA30AZB Memo ...
Page 87: ...87 KX TGD320ALB KX TGD322ALB KX TGD323ALB KX TGDA30AZB 15 4 Accessories A2 A1 A3 ...