KX-TG9581B/KX-TG9582B/KX-TGA950B
11 Measurements and Adjustments
This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in
11.1. Equipment Required
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm).
Hewlett Packard, 53131A is recommended.
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope
11.2. The Setting Method of JIG
<Preparation>
• Serial JIG cable: PQZZ1CD300E
• PC which runs in DOS mode
•
Batch file CD-ROM
for setting: PNZZTG9581B
11.2.1.
Connections (Base Unit)
Connect the AC adaptor to DC-JACK (base unit).
Connect the JIG Cable GND (black) to GND.
Connect the JIG Cable RX (red) to URX and TX (yellow) to UTX.
Note:
*: COM port names may vary depending on what your PC calls it.
2
GND (black)
3
To Serial Port
(com port 1*)
JIG Cable
PC
M_UTX (yellow)
3
M_URX (red)
Base Unit P. C. board
1
Use Download program for IC60
3
GND
M_UTX
S_UTX
M_URX
S_URX
AC Adaptor
To Serial Port
(com port 1*)
PC
Use Download program for IC70
3
S_URX(red)
S_UTX (yellow)
3