50
KX-TG8411HGB/KX-TGA840FXB
9.3.
Troubleshooting by Symptom (Handset)
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not.
Note:
(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to
Check Point (Handset)
(P.50)
9.3.1.
Check Point (Handset)
Please follow the items below when BBIC or EEPROM is replaced.
Note:
After the measuring, suck up the solder of TP.
*:
The Setting Method of JIG (Handset)
(P.62) is required beforehand.
The connections of adjustment equipment are as shown in
Adjustment Standard (Handset)
(P.64).
Items
Check
Point
Procedure
Check or
Replace Parts
(
A
)* 1.8 V Supply Adjustment
VDD1
1. Confirm that the voltage between test point VDD1 and GND is 1.8 V ± 0.02 V.
2. Execute the command “VDD”, then check the current value.
3. Adjust the 1.8V voltage of VDD1 executing command “VDD XX“(XX is the
value).
IC1, Q2, C48,
D1, C1, C44,
R12, R45,
C40, C45, F1
(
B
)*
BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC1, X1, RA61,
R64, R66
(
C
)* EEP-ROM Confirmation
-
1. EEP-ROM Confirmation (Execute the command "sendchar EPV").
2. Confirm the returned Value (Value for reference is written at "EEPROM C/
SUM" in Software_Version_Table.xls).
IC1, IC3,
R40~R42,
C172
(D) Charge Control Check &
Charge Current Monitor
Check
-
1. Apply 3.5 V between CHG(+) and CHG(-) with DC power supply and set cur-
rent limit to 250 mA.
Confirm the indication of “charging” on LCD.
2. Confirm that the current limit LED of DC power supply is ON/OFF.
Confirm it after waiting over 1 minute at least.
3. Decrease current limit of DC power supply to 100 mA.
4. Confirm that the current limit LED of DC power supply is stable. (Current limiter
is ON.)
(If charge control cannot be confirmed by this procedure, please use battery to hand-
set power supply and try again.)
IC1, Q4 Q9,
D7, R6, R7,
F1, C1, R2,
R30, R31, R8,
R45
(
E
)* Charge Detection (OFF)
Check
-
1. Stop supplying 3.5 V to CHG (+) and CHG (-).
2. Confirm the indication of “charging” has been cleared.
IC1, Q4 Q9,
D7, R6, R7,
F1, C1, R2,
R30, R31, R8,
R45
Summary of Contents for KX-TG8411HGB
Page 2: ...2 KX TG8411HGB KX TGA840FXB ...
Page 14: ...14 KX TG8411HGB KX TGA840FXB 4 6 Signal Route ...
Page 22: ...22 KX TG8411HGB KX TGA840FXB 7 6 Troubleshooting ...
Page 23: ...23 KX TG8411HGB KX TGA840FXB Cross Rreference For Service Hint P 26 ...
Page 24: ...24 KX TG8411HGB KX TGA840FXB ...
Page 25: ...25 KX TG8411HGB KX TGA840FXB ...
Page 26: ...26 KX TG8411HGB KX TGA840FXB 7 7 For Service Hint Cross Reference Battery Charge P 16 ...
Page 27: ...27 KX TG8411HGB KX TGA840FXB 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Page 29: ...29 KX TG8411HGB KX TGA840FXB 8 1 2 Handset ...
Page 38: ...38 KX TG8411HGB KX TGA840FXB Cross Reference Check Point Base Unit P 46 ...
Page 40: ...40 KX TG8411HGB KX TGA840FXB Cross Reference Check Point Handset P 50 ...
Page 55: ...55 KX TG8411HGB KX TGA840FXB 10 1 2 Handset ...
Page 56: ...56 KX TG8411HGB KX TGA840FXB 10 1 3 Charger Unit ...
Page 57: ...57 KX TG8411HGB KX TGA840FXB 10 2 How to Replace the Handset LCD ...
Page 79: ...79 KX TG8411HGB KX TGA840FXB Memo ...
Page 92: ...92 KX TG8411HGB KX TGA840FXB 15 3 Cabinet and Electrical Parts Charger Unit ...
Page 93: ...93 KX TG8411HGB KX TGA840FXB 15 4 Accessories and Packing Materials 15 4 1 KX TG8411HGB ...
Page 94: ...94 KX TG8411HGB KX TGA840FXB 15 4 2 KX TGA840FXB ...