44
KX-TG8107UA/KX-TG8108UA/KX-TGA810UA
9.2.2.
Check Point (Charger Unit)
Note:
After the measuring, suck up the solder of TP.
The connection of adjustment equipment is as shown in
Adjustment Standard (Charger Unit)
Items
Check
Point
Procedure
Check or
Replace Parts
(
A
)
Charging Check
-
1. Connect Charge Contact 12
Ω
/2W resistor between and charge-.
2. Measure and confirm voltage across the resistor is 3.3V ± 0.2V.
R2, R1, R3, R4