62
KX-TG8105RU/KX-TG8106RU/KX-TGA810RU
11.6. Things to Do after Replacing IC
Cautions:
Some of the content on this page may not apply to models from some countries. The contents below are the minimum adjust-
ments required for operation.
11.6.1. Base Unit
Before making the following adjustment, ensure you have carried out
The Setting Method of JIG (Base
Note:
(*1) XX: country code, YY: revision number
“XX” and “YY” vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in
(P.55).
(*2) Refer to
11.6.2. Handset
Before making the following adjustment, ensure you have carried out
(P.59) in
The Setting Method of JIG (Hand-
.
Note:
(*3) XX: country code, YY: revision number
“XX” and “YY” vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in
(*4) Refer to
IC
Necessary Adjustment
BBIC
(IC7)
Programs for Voice processing, interface for RF and
EEPROM
1. Default batch file: Execute the command “default.bat”.
2. Country version batch file: Execute the command
“TG8100XXrevYY.bat”. (*1)
3. Clock adjustment: Refer to Check Point (F). (*2)
EEPROM
(IC5)
Adjustment parameter data
(country version batch file, default batch file, etc.)
1. Change the address “0000” of EEPROM to “AA”.
2. Default batch file: Execute the command “default.bat”.
3. Country version batch file: Execute the command
“TG8100XXrevYY.bat”. (*1)
4. Clock adjustment: Refer to Check Point (F). (*2)
IC
Necessary Adjustment
BBIC
(IC1)
Programs for Voice processing, interface for RF and
EEPROM
1. Default batch file: Execute the command “default.bat”.
2. Default batch file (remaining); Execute the command
“TGA810DEFrevYY.bat”. (*3)
3. Country version batch file: Execute the command
“TGA810XXrevYY”. (*3)
4. Clock adjustment: Refer to Check Point (J). (*4)
5. 1.8 V setting and battery low detection: Refer to Check
Point (A), (H) and (I). (*4)
EEPROM
(IC3)
Adjustment parameter data
(country version batch file, default batch file, etc.)
1. Change the address “0015” of EEPROM to “55”.
2. Default batch file: Execute the command “default.bat”.
3. Default batch file (remaining); Execute the command
“TGA810DEFrevYY.bat”. (*3)
4. Country version batch file: Execute the command
“TGA810XXrevYY”. (*3)
5. Clock adjustment: Refer to Check Point (J). (*4)
6. 1.8 V setting and battery low detection: Refer to Check
Point (A), (H) and (I). (*4)
Summary of Contents for KX-TG8105RU
Page 2: ...2 KX TG8105RU KX TG8106RU KX TGA810RU ...
Page 6: ...6 KX TG8105RU KX TG8106RU KX TGA810RU 3 Specifications ...
Page 12: ...12 KX TG8105RU KX TG8106RU KX TGA810RU 4 6 Signal Route ...
Page 17: ...17 KX TG8105RU KX TG8106RU KX TGA810RU 7 2 Handset Settings ...
Page 20: ...20 KX TG8105RU KX TG8106RU KX TGA810RU 7 3 2 Cancelling a Base Unit 7 4 For Service Hint ...
Page 21: ...21 KX TG8105RU KX TG8106RU KX TGA810RU 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Page 24: ...24 KX TG8105RU KX TG8106RU KX TGA810RU 8 1 2 Handset ...
Page 38: ...38 KX TG8105RU KX TG8106RU KX TGA810RU Cross Reference Check Point Base Unit P 42 ...
Page 52: ...52 KX TG8105RU KX TG8106RU KX TGA810RU 10 1 2 Handset ...
Page 53: ...53 KX TG8105RU KX TG8106RU KX TGA810RU 10 1 3 Charger Unit ...
Page 83: ...83 KX TG8105RU KX TG8106RU KX TGA810RU 15 3 Cabinet and Electrical Parts Charger Unit ...
Page 85: ...85 KX TG8105RU KX TG8106RU KX TGA810RU 15 4 2 KX TG8106RUS RUT ...
Page 86: ...86 KX TG8105RU KX TG8106RU KX TGA810RU 15 4 3 KX TGA810RUS RUT ...