52
KX-TG6841BXB/KX-TGA680BXB
12 Measurements and Adjustments
This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in
12.1. Equipment Required
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm)
Hewlett Packard, 53131A is recommended.
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
This equipment may be useful in order to precisely adjust like a mass production.
12.2. The Setting Method of JIG
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
•
Batch file CD-ROM
for setting: PNZZTG6841BX
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
12.2.1. Connections (Base Unit)
Connect the AC adaptor.
Connect the JIG Cable GND (black).
Connect the JIG Cable RX (red) and TX (yellow).
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor
Old value (k
)
New value (k
)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
Base unit P. C. board
AC adaptor
1
DC JACK
UTX (yellow)
3
2
3
GND (black)
URX (red)
To Serial Port
(COM port 1*)
JIG Cable
PC
GND
UTX
URX
Summary of Contents for KX-TG6841BXB
Page 66: ...66 KX TG6841BXB KX TGA680BXB Memo ...
Page 71: ...71 KX TG6841BXB KX TGA680BXB Memo ...
Page 73: ...73 KX TG6841BXB KX TGA680BXB Memo ...
Page 76: ...76 KX TG6841BXB KX TGA680BXB Memo ...
Page 80: ...80 KX TG6841BXB KX TGA680BXB Memo ...
Page 85: ...85 KX TG6841BXB KX TGA680BXB 16 3 Accessories A1 A2 A3 ...