40
KX-TGF350N/KX-TGF352N/KX-TGF353N/KX-TG572SK/KX-TGF380M/KX-TGF382M/KX-TGF383M/KX-TGFA30N/KX-TGFA30M
10.1.6.2. RF Check Flowchart
Each item (1 ~ 5) of RF Check Flowchart corresponds to
Check Table for RF part
(P.41).
Please refer to the each item.
Note:
(*1) Refer to
Check Link
(P.37).
Start
Link
confirmation
Normal
1
Control
signal
confirmation
X'tal
Frequency
confirmation
TX confirmation
Range
confirmation
Normal
TEST RANGE Check.
Check BBIC interface parts.
(RF Block <->BBIC on BU/HS P.C.B)
Adjust X'tal Frequency. (*1)
Check TX Block.
GOOD
5
2
3
4
OK
OK
OK
NG
NG
NG
NG
NG
OK
OK