13.7.4. TEST RANGE Check
Circuit block which range is defective can be found by the following check.
Item
BU (Base Unit) Check
HS (HandSet) Check
Range Confirmation TX
TEST
(TX Power check)
HS, BU Mode:
[Test Link Mode] (*1)
1. Register Regular HS to BU (to be checked).
2. Set BU to “Test Link mode”.
3. Set Regular HS to “Test Link mode”.
*Set TX Power and RX Sensitivity ofthe BU and the
Regular HS by CHART1.
* At distance ofabout 20m between HS and BU,
Link OK = TX Power ofthe BU is OK.
No Link = TX Power ofthe BU is NG.
1. Register HS (to be checked) to Regular BU.
2. Set Regular BU to “Test Link mode”.
3. Set HS to “Test Link mode”.
*Set TX Power and RX Sensitivity ofthe HS and the
Regular BU by CHART1.
* At distance ofabout 20m between HS and BU,
Link OK = TX Power ofthe HS is OK.
No Link = TX Power ofthe HS is NG.
Range Confirmation RX
TEST
(RX sensitivity check)
HS, BU Mode:
[Test Link Mode] (*1)
1. Register Regular HS to BU (to be checked).
2. Set BU to “Test Link mode”.
3. Set Regular HS to “Test Link mode”.
*Set TX Power and RX Sensitivity ofthe BU and
Regular HS by CHART1.
* At distance ofabout 20m between HS and BU,
Link OK= RX Sensitivity ofthe BU is OK.
No Link = RX Sensitivity ofthe BU is NG.
1. Register HS (to be checked) to Regular BU.
2. Set Regular BU to “Test Link mode”.
3. Set HS to “Test Link mode”.
* Set TX Power and RX Sensitivity ofChecking_HS
and Regular_BU by CHART1.
* At distance ofabout 20m between HS and BU,
Link OK= RX Sensitivity ofthe HS is OK.
No Link = RX Sensitivity ofthe HS is NG
CHART1: Setting of TX Power and RX Sensitivity in Range Confirmation TX TEST, RX TEST
BU (to be checked)
Regular_HS
TX Power
RX Sens.
TX Power
RX Sens.
BU (Base Unit) TX Power Check
High
High
High
Low
BU (Base Unit) RX Sensitivity Check
High
High
Low
High
HS (to be checked)
Regular_BU
TX Power
RX Sens.
TX Power
RX Sens.
HS (Handset) TX Power Check
High
High
High
Low
HS (Handset) RX Sensitivity Check
High
High
Low
High
Note:
(*1)
ADJUSTMENT AND TEST MODE
(P.51)
47
KX-TG5431BXS / KX-TGA542BXS
Summary of Contents for KX-TG5431BXS
Page 9: ...5 LOCATION OF CONTROLS 5 1 Base Unit 5 2 Handset 9 KX TG5431BXS KX TGA542BXS ...
Page 10: ...5 2 1 How to Use the Soft Keys Navigator Key 10 KX TG5431BXS KX TGA542BXS ...
Page 11: ...6 DISPLAYS 6 1 Display Items 11 KX TG5431BXS KX TGA542BXS ...
Page 13: ...7 SETTINGS 7 1 Connections 13 KX TG5431BXS KX TGA542BXS ...
Page 15: ...7 4 Date and Time 15 KX TG5431BXS KX TGA542BXS ...
Page 16: ...7 5 Dialing Mode 7 6 Line Mode 7 7 Flash Button 16 KX TG5431BXS KX TGA542BXS ...
Page 17: ...7 8 Voice Enhancer 7 9 Handset Ringer Tone 17 KX TG5431BXS KX TGA542BXS ...
Page 20: ...Cross Reference Remote Code P 29 Re registering the Handset P 44 20 KX TG5431BXS KX TGA542BXS ...
Page 21: ...8 OPERATION 8 1 Phonebook 8 1 1 Adding Items to the Phonebook 21 KX TG5431BXS KX TGA542BXS ...
Page 29: ...9 6 1 Using the Answering System Remotely 9 6 2 Remote Code 29 KX TG5431BXS KX TGA542BXS ...
Page 48: ...13 7 5 RF DSP Interface Signal Wave Form Test Burst Mode 48 KX TG5431BXS KX TGA542BXS ...
Page 49: ... Test Burst Mode 49 KX TG5431BXS KX TGA542BXS ...
Page 91: ...24 SIGNAL ROUTE Each signal route is as follows 91 KX TG5431BXS KX TGA542BXS ...
Page 92: ...Each signal route is as follows RF part signal route 92 KX TG5431BXS KX TGA542BXS ...
Page 95: ...27 EXPLANATION OF IC TERMINALS RF PART 27 1 IC701 95 KX TG5431BXS KX TGA542BXS ...
Page 96: ...27 2 IC801 Backside Terminal GND 96 KX TG5431BXS KX TGA542BXS ...
Page 97: ...27 3 IC851 Backside Terminal GND 97 KX TG5431BXS KX TGA542BXS ...
Page 100: ...29 CABINET AND ELECTRICAL PARTS BASE UNIT 100 KX TG5431BXS KX TGA542BXS ...
Page 101: ...30 CABINET AND ELECTRICAL PARTS HANDSET 101 KX TG5431BXS KX TGA542BXS ...
Page 102: ...31 ACCESSORIES AND PACKING MATERIALS 31 1 KX TG5431BXS 102 KX TG5431BXS KX TGA542BXS ...
Page 115: ...Memo 115 KX TG5431BXS KX TGA542BXS ...
Page 120: ...Memo 120 KX TG5431BXS KX TGA542BXS ...
Page 126: ...Memo KX TG5431BXS KX TGA542BXS 126 ...
Page 130: ...130 KX TG5431BXS KX TGA542BXS G N KXTG5431BXS KXTGA542BXS ...