25
KX-TG3411BX/KX-TG3412BX/KX-TG3419BX/KX-TGA341BX
Frequently Used Items (Base Unit)
ex.)
Note:
(*1) Refer to
Registering a Handset to the Base Unit
(P.38).
(*2) When you enter the address or New Data, please refer to the table below.
(*3)
Items
Address
Default Data
New Data
Remarks
C-ID (DTMF) sensitivity
05 6C
00
01 (6 dB up)
02 (12 dB up) When hex changes from “00” to “01” or “02”,
gain increases by 6 dB or 12 dB.
Frequency
00 08/00 07
02/70
-
-
Use these items in a
READ-ONLY
mode to
confirm the contents. Careless rewriting may
cause serious damage to the computer system.
ID
00 02~00 06
Given value
-
-
Bell length
02 45
64 (10sec) (*3)
1E (3 sec)
14 (2 sec)
This is time until bell stops ringing.
(Unit: 100 ms)
Time Adjustment
0F 3B
00 (“Manual”) 01 (“Caller ID”)
-
This feature allows the unit to automatically
adjust the date and time each time caller
information including date and time is received.
To turn this feature on, select “Caller ID”. To
turn this feature off, select “Manual”. (Caller ID
subscribers only) To use this feature, set the
date and time first.
Desired Number (hex)
Input Keys
Desired Number (hex)
Input Keys
0
0
A
[FLASH] + 0
1
1
B
[FLASH] + 1
.
.
C
[FLASH] + 2
.
.
D
[FLASH] + 3
.
.
E
[FLASH] + 4
9
9
F
[FLASH] + 5
Bell length
64(hex) = 100(dec)
→
100
×
100 msec = 10000 msec (10 sec)