13.3.1. Charge Circuit
The voltage from the AC is supplied to the charge circuits. Main charge (180mA at the Battery) of maximum 6-hours is started
soon after the Handset is placed on the Base Unit. Then it changes to Trickle charge to prevent from overcharging.
Q361 and Q362 detect the ON-HOOK state (Handset is placed on Base Unit).
Q371 and Q372 control the charge current.
52