11.7.3. Check Table for RF part
No.
Item
BU checking
HS checking
1a Link confirmation Normal
1.
Re-resister HS Regular Unit (working) to BU.
2.
Press [Talk] key of the HS Regular Unit to
establish link.
1.
Re-resister HS to BU of Regular Unit (working).
2.
Press [Talk] key of the HS to establish link.
1b Link confirmation TX Test
1.
Re-resister HS Regular Unit (working) to BU.
2.
Set BU to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:High)
3.
Set HS Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:Low)
4.
Press [1] key of HS Regular Unit to establish link
about 5m away from BU.
5.
Press [1] key of HS Regular Unit to set RSSI
mode, and press [2] key to set RX Gain Low.
6.
Confirm the value of RSSI in LCD of HS Regular
Unit is more than "e0(hex)".
1.
Re-resister HS to BU Regular Unit (working).
2.
Set BU Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:Low)
3.
Set HS to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:High)
4.
Press [1] key of HS to establish link about 5m
away from BU of Regular Unit.
5.
Press [REC] key of BU Regular Unit to set RSSI
mode, and press [GREETING CHECK] key to set
RX Gain Low.
6.
Confirm the value of RSSI in LCD of BU Regular
Unit is more than "e0(hex)".
1c Link confirmation RX Test 1.
Re-resister HS Regular Unit (working) to BU.
2.
Set BU to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:Low)
3.
Set HS Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:High)
4.
Press [1] key of HS Regular Unit to establish link
about 5m away from BU.
5.
Press [REC] key of BU to set RSSI mode, and
press [GREETING CHECK] key to set RX Gain
Low.
6.
Confirm the value of RSSI in LCD of BU is more
than "e0(hex)".
1.
Re-resister HS to BU of Regular Unit (working).
2.
Set BU Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:High)
3.
Set HS to TEST Link mode. (*1)
(CH:45ch / TX Power:Low / RX Gain:Low)
4.
Press [1] key of HS to establish link about 5m
away from BU Regular Unit.
5.
Press [1] key of HS to set RSSI mode, and press
[2] key to set RX Gain Low.
6.
Confirm the value of RSSI in LCD of HS is more
than "e0(hex)".
2
Control signal confirmation 1.
Set TX Burst mode.(*1)
2.
Check DSP interface.(*2)
1.
Set TX Burst mode.(*1)
2.
Check DSP interface.(*2)
3
X’tal Frequency
confirmation(*5)
1.
Adjust X’tal mode.(*1)
2.
Check X´tal Frequency.
(13.824000MHz±100Hz)
1.
Adjust X’tal mode.(*1)
2.
Check X´tal Frequency.
(13.824000MHz±100Hz)
4
TX Power confirmation
1.
Set BU to TX Burst mode at 45ch. (*1)
(TX Power:High)
2.
Set HS Regular Unit to RX-CW TEST mode at
45ch (RX Gain is fixed Low Gain). (*1)
3.
Place HS Regular Unit about 5m away from BU.
4.
Confirm RSSI of HS Regular Unit is more than
1.75V by Oscilloscope. (*4)
1.
Set HS to TX Burst mode at 45ch. (*1)
(TX Power:High)
2.
Set BU Regular Unit to RX-CW TEST mode at
45ch (RX Gain is fixed Low Gain). (*1)
3.
Place HS about 5m away from BU Regular Unit.
4.
Confirm RSSI of BU Regular Unit is more than
1.75V by Oscilloscope.(*3)
5
RX Sensitivity confirmation 1.
Set BU to RX-CW TEST mode at 45ch (RX Gain
is fixed Low Gain). (*1)
2.
Set HS Regular Unit to TX Burst mode at 45ch.
(*1) (TX Power:High)
3.
Place HS Regular Unit about 5m away from BU.
4.
Confirm RSSI of BU is more than 1.75V by
Oscilloscope.(*3)
1.
Set HS to RX-CW TEST mode at 45ch (RX Gain
is fixed Low Gain). (*1)
2.
Set BU Regular Unit to TX Burst mode at 45ch.
(*1) (TX Power:High)
3.
Place HS about 5m away from BU Regular Unit.
4.
Confirm RSSI of HS is more than 1.75V by
Oscilloscope.(*4)
Note:
(*1) TEST MODE (P.37)
(*2) RF-DSP interface signal wave form (P.35)
(*3) CIRCUIT BOARD (BASE UNIT) Component View (P.89)
(*4) CIRCUIT BOARD (HANDSET) Component View (P.93)
(*5) X801 (Base Unit), X201 (Handset) Check (P.44)
34
KX-TG2323AGB / KX-TGA231AGB
Summary of Contents for KX-TG2323AGB
Page 8: ...4 4 Battery Replacement 8 KX TG2323AGB KX TGA231AGB ...
Page 9: ...5 LOCATION OF CONTROLS 5 1 Base Unit 9 KX TG2323AGB KX TGA231AGB ...
Page 10: ...5 2 Handset 10 KX TG2323AGB KX TGA231AGB ...
Page 11: ...6 DISPLAY 6 1 Base Unit Display 11 KX TG2323AGB KX TGA231AGB ...
Page 12: ...7 SETTINGS 7 1 Connections 12 KX TG2323AGB KX TGA231AGB ...
Page 13: ...7 2 Connecting an Optional Headset 7 3 Time and Day 13 KX TG2323AGB KX TGA231AGB ...
Page 14: ...7 4 Dialing Mode 7 5 Voice Enhancer Technology 7 6 Ringer Tone 14 KX TG2323AGB KX TGA231AGB ...
Page 15: ...8 OPERATION 8 1 Answering System 8 1 1 Greeting Message 15 KX TG2323AGB KX TGA231AGB ...
Page 16: ...16 KX TG2323AGB KX TGA231AGB ...
Page 17: ...8 1 2 Erasing Messages 8 2 For Call Waiting Service Users 17 KX TG2323AGB KX TGA231AGB ...
Page 18: ...8 3 FLASH Button 8 4 Remote Operation from a Touch Tone Phone 18 KX TG2323AGB KX TGA231AGB ...
Page 19: ...8 4 1 Summary of Remote Operation 8 4 2 Remote Code 19 KX TG2323AGB KX TGA231AGB ...
Page 21: ...8 4 7 Recording Your Own Message Marker Message 21 KX TG2323AGB KX TGA231AGB ...
Page 35: ...11 7 4 RF DSP interface signal wave form 35 KX TG2323AGB KX TGA231AGB ...
Page 38: ...12 1 2 RX CW TEST Mode 38 KX TG2323AGB KX TGA231AGB ...
Page 39: ...12 1 3 Test Link Mode Note 1 for factory use only 39 KX TG2323AGB KX TGA231AGB ...
Page 40: ...12 2 Test Mode Flow Chart for Handset 12 2 1 TX Burst Mode 40 KX TG2323AGB KX TGA231AGB ...
Page 41: ...12 2 2 RX CW TEST Mode 41 KX TG2323AGB KX TGA231AGB ...
Page 42: ...12 2 3 Test Link Mode Note 1 for factory use only 42 KX TG2323AGB KX TGA231AGB ...