39
KX-TG1711LAB/KX-TGA171LAB
11.5. Things to Do after Replacing IC
Cautions:
Since this page is common to each country, it may not apply to some models in your country. The contents below are the
minimum adjustments required for operation.
11.5.1. Base Unit
Before doing the following adjustment, be sure to do
PC Setting
(P.33) in
The Setting Method of JIG (Base Unit)
.
Note:
(*1) Refer to
Check Point (Base Unit)
(P.24)
(*2) xx: country code, yyy: revision number
“xx” and “yyy” vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in
JIG and PC
(P.33).
11.5.2. Handset
Before doing the following adjustment, be sure to do
PC Setting
(P.36) in
The Setting Method of JIG (Handset)
.
Note:
(*3) Refer to
Check Point (Handset)
(P.27)
(*4) xx: country code, yyy: revision number
“xx” and “yyy” vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in
JIG and PC
(P.36).
IC
Necessary Adjustment
BBIC
Programs for Voice processing, interface for RF and
EEPROM
1. Clock adjustment: Refer to Check Point (D). (*1)
EEPROM Adjustment parameter data
(country version batch file, default batch file, etc.)
1. Default batch file: Execute the command “DefaultEEP”.
2. Country version batch file: Execute the command
“TG16XX_FP_ROM2_xx_yyy.bat”. (*2)
3. Clock adjustment: Refer to Check Point (D). (*1)
IC
Necessary Adjustment
BBIC
Programs for Voice processing, interface for RF
and EEPROM
1. Clock adjustment: Refer to Check Point (H). (*3)
2. 4.0 V setting and battery low detection: Refer to Check Point (A),
(F) and (G). (*3)
EEPROM Adjustment parameter data
(country version batch file, default batch file, etc.)
1. Default batch file: Execute the command “Default”.
2. Melody Initialize batch file; Execute the Command "Melody_008".
3. Country version batch file: Execute the command
"TG16XX_PP_xx_yyy.bat".
4. Clock adjustment: Refer to Check Point (H). (*3)
5. 4.0 V setting and battery low detection: Refer to Check Point (A),
(F) and (G). (*3)