Serial JIG
JIG Cable: PQZZ1CD300E*
•
PC which runs in DOS mode.
•
Batch file CD-ROM
for setting: PQZZTG1233BX
Note:
*: If
you
have
the
JIG
Cable
for
TCD500
series
(PQZZ1CD505E),
change
the
following
values
of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
Resistor
Old value (k
Ω
)
New value (k
Ω
)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
9.3. The Setting Method of JIG (Handset)
9.3.1. Preparation
9.3.1.1. Equipment Required
•
DECT tester: Rohde & Schwarz, CMD 60 is recommended.
•
Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4ppm).
Hewlett Packard, 53131A is recommended.
•
DC power: it must be able to output at least 1A current under 2.4V for Handset.
•
Digital multi-meter (DMM): it must be able to measure voltage and current.
•
Oscilloscope
9.3.1.2. JIG and PC
9.3.2. PC Setting
9.3.2.1. Connections
Connect the DC Power or Battery to BAT+ and BAT- (Handset).
Connect the JIG Cable GND (black).
Connect the JIG Cable UTX (yellow) and URX (red).
Note:
*: COM port names may vary depending on what your PC calls it.
40
KX-TG1233BXS / KX-TG1233B XT / KX-TCA122CXS / KX-TCA122CXT / KX-TCA121CXS / KX-TCA121CXT
Summary of Contents for KX-TG1233BXT
Page 54: ...54 KX TG1233BXS KX TG1233BXT KX TCA122CXS KX TCA122CXT KX TCA121CXS KX TCA121CXT ...
Page 63: ...22 2 Handset 63 KX TG1233BXS KX TG1233BXT KX TCA122CXS KX TCA122CXT KX TCA121CXS KX TCA121CXT ...
Page 84: ...Memo 84 KX TG1233BXS KX TG1233BXT KX TCA122CXS KX TCA122CXT KX TCA121CXS KX TCA121CXT ...
Page 89: ...Memo 89 KX TG1233BXS KX TG1233BXT KX TCA122CXS KX TCA122CXT KX TCA121CXS KX TCA121CXT ...