Note for KX-NT265 IP-PT users
The supported card varies depending on the software version of your KX-NT265 IP-PT. To confirm the version,
follow the procedure below:
"
AP Version
".
Select
"Maintenance".
Software version
is displayed.
While starting up
Select
"Version display".
To exit the programming mode
PROGRAM
SP-PHONE
SP-PHONE
SP-PHONE
HOLD
HOLD
HOLD
HOLD
Power Supply Unit Selection
The PBX needs a power supply unit (PSU) suitable for its configuration. Calculate the load figure from the type
and number of items of equipment to be connected, and determine the type of PSU that will be required.
Load Figure Calculation
Equipment Type
Load Figure
PT
KX-DT300 series DPT/KX-DT300 series DSS
console/KX-T7600 series DPT/KX-T7600 series
DSS console
1
KX-T7560/KX-T7565 DPT
1
Other DPT/Other DSS console
4
APT
4
IP-PT
0
SIP Extension
0
Extension Card
DHLC8
8
SLC8
8
SLC16/MSLC16/CSLC16
16
CS (1 unit)
4
High-density CS (1 unit)
8
IP-CS (1 unit)
0
ISDN Extension
2
VPS (1 port)
1
*1
Only the extension cards that can support SLTs count for the load figures.
Installation Manual
37
1.3.3 System Capacity
Summary of Contents for KX-TDE200
Page 20: ...20 Installation Manual Table of Contents...
Page 172: ...172 Installation Manual 3 13 1 Starting the PBX...
Page 192: ...192 Installation Manual 5 1 5 Troubleshooting by Error Log...
Page 193: ...Section 6 Appendix Installation Manual 193...
Page 197: ...Index Installation Manual 197...
Page 203: ...Installation Manual 203 Notes...