Units, Weights and Specifications subject to change.
16
version 1.2
KX-TDE100 & KX-TDE200 POWEr SUPPLY
It is necessary to select the proper power supply for the system in accordance with the type and number of extensions that are connected to
the system. There are 3 power supply options; S = Small, M = Medium and L = Large. To calculate the size of the power supply required for
your application, you must determine the type of telephone extensions you plan to use. Then using the telephone equipment power factor
“B” portion of the chart below, calculate the point value for each and add up all the points. Using the Power Supply Maximum Power Factor
“A” portion of the chart below, match up the points calculated with the correct power supply. The power supply value must be greater than
the total points calculated for the telephone equipment. (When in doubt use the larger power supply.)
A - Power Supply Maximum Power Factors
TDE100
TDE200
Power Supply Model
KX-TDA0108 (S Type)
KX-TDA0104 (M Type)
KX-TDA0104 (M Type)
KX-TDA0103 (L Type)
Maximum Power Factor
64
128
128
512
B - Telephone Equipment Power Factor
Telephone Equipment
Point Value
For Each
T7600 Digital Series (KX-TDA Digital System Phones)
1
KX-T7400 & KX-T7200 Digital Series (KX-TD Digital System Phones)
4
KX-T7000, KX-T7300, KX-T7700 Series and DSS Consoles (KX-T & KX-TA Hybrid System Phones)
4
IP Telephones (KX-NT SERIES)
0
SIP Extensions
0
SLT* Cards
(Single Line Telephones)
SLC8
8
SLC16
16
MSLC16
16
DHLC8
8
Cell Station (KX-T0151, KX-T0155, & KX-TDA0152)
4
High density cell station (1 unit)
8
KX-TVA & KX-NCV Voice Mail Port Connection (2 ch)
1
*
Calculation must be based on the number of cards, not the number of telephones.
CHArT #1
Summary of Contents for KX-TDE100
Page 22: ...Units Weights and Specifications subject to change 22 VERSION 1 2 Notes...
Page 23: ...Units Weights and Specifications subject to change 23 VERSION 1 2 Notes...
Page 24: ...Units Weights and Specifications subject to change 24 VERSION 1 2 Notes...
Page 25: ...Units Weights and Specifications subject to change 25 VERSION 1 2 Notes...
Page 26: ...Units Weights and Specifications subject to change 26 VERSION 1 2 Notes...
Page 27: ...VERSION 1 2 Notes 27...
Page 28: ...Units Weights and Specifications subject to change 28 VERSION 1 2 Notes...