4 SPECIFICATIONS
4.1. GENERAL DESCRIPTION
Control Bus
Original bus (16 bit, 8 MHz,10 megabytes per second)
Communication Bus
H.100 bus conformity (1024 time slot)
Switching
Distributed Switching
Power Input
PSU-M
100 V AC to 130 V AC, 2.5 A/200 V AC to 240 V AC, 1.4 A, 50 Hz/60 Hz
PSU-L
100 V AC to 130 V AC, 5.1 A/200 V AC to 240 V AC, 2.55 A, 50 Hz/60 Hz
External Battery
+36 V DC (+12 V DC x 3, recommended maximum current per shelf is 28 Ah or lower)
Maximum Power Failure Tolerance
300 ms (without using backup battery)
Memory Backup Duration
7 years
Dialling
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
Trunk Loop Limit
1600
Ω
maximum
Operating
Environment
Temperature
0 °C to 40 °C
Humidity
10%to 90% (non-condensing)
Conference Call Trunk (per shelf)
From 10 x 3-party conference call to 4 x 8-party conference call
Music on Hold (MOH)
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Paging
Internal
Level Control: -15 dB to +6 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
Serial Interface Port
RS-232C
1 (max 115.2 kbps)
USB
1
Extension Connection Cable
SLT
1 pair wire (T, R)
DPT
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
APT
2-pair wire (T, R, D1, D2)
PT-interface CS
1-pair wire (D1, D2)
DSS Consoles and Add-on Key Module
1-pair wire (D1, D2)
Dimension
Basic Shelf
430 mm (W) x 415 mm (H) x 270 mm (D)
(17 1/5 in x 16 3/5 in x 10 4/5 in)
Weight (when fully mounted) Basic Shelf
Under 16 kg (35.2 lb)
4.2. CHARACTERISTICS
Terminal Equipment Loop Limit
•
•
•
•
PT: KX-T7600 series DPT: 90
Ω
; all other DPTs/APTs: 40
Ω
•
•
•
•
SLT: 600
Ω
including set
•
•
•
•
Doorphone: 20
Ω
•
•
•
•
CS: 130
Ω
; PT-interface CS: 65
Ω
Minimum Leakage Resistance
15000
Ω
maximum
Maximum Number of Extension
Instruments per Line
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT
3 by Digital eXtra Device Port connection of 2 DPTs and an SLT
Ring Voltage
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Trunk Loop Limit
1600
Ω
maximum
Hookswitch Flash/Recall Timing Range
24 ms to 2032 ms
BRI Cards Internal ISDN Mode
Supply Voltage: 40 V
Power Supply (BRI4): 4.5 W per 1 line, 10 W per 4 lines
Power Supply (BRI8): 4.5 W per 1 line, 20 W per 8 lines
Power Supply Method: Phantom Power Supply
Door Opener Current Limit
24 V DC/30 V AC, 1 A maximum
External Relay Current Limit
24 V DC/30 V AC, 1 A maximum
External Sensor Current Limit
Power to the external sensor is provided from the EIO4 card and must be grounded through
the EIO4 card. The Hybrid IP-PBX detects input from the sensor when the signal is under
100
Ω
Paging Terminal Impedance
600
Ω
MOH (Music on Hold) Terminal Impedance
10000
Ω
6
KX-TDA600BX
Summary of Contents for KX-TDA600BX
Page 4: ...1 2 HOW TO RECOGNIZE THAT Pb FREE SOLDER IS USED 4 KX TDA600BX ...
Page 14: ...5 SYSTEM OVERVIEW 5 1 SYSTEM CONFIGURATIONS 14 KX TDA600BX ...
Page 17: ...5 3 SYSTEM CONNECTION DIAGRAM 17 KX TDA600BX ...
Page 23: ...7 2 SYSTEM CONTROL 7 2 1 System Control Block Diagram 23 KX TDA600BX ...
Page 24: ...7 2 2 Voice TDM Highway Bus Block Diagram 24 KX TDA600BX ...
Page 27: ...7 3 2 EC Bus System Connection Diagram 27 KX TDA600BX ...
Page 38: ...10 TROUBLESHOOTING GUIDE 10 1 EMPR 10 1 1 Startup 38 KX TDA600BX ...
Page 39: ...39 KX TDA600BX ...
Page 40: ...40 KX TDA600BX ...
Page 41: ...41 KX TDA600BX ...
Page 42: ...10 1 1 1 Main alarm light turns on 42 KX TDA600BX ...
Page 43: ...10 1 1 2 SD card access light does not flash 43 KX TDA600BX ...
Page 44: ...10 1 1 3 The battery alarm indication light turns on 44 KX TDA600BX ...
Page 45: ...10 1 1 4 Main alarm indication light flashes 45 KX TDA600BX ...
Page 46: ...10 1 1 5 Option card cannot start up 46 KX TDA600BX ...
Page 47: ...10 1 2 Phone Call 10 1 2 1 The path cannot connect 47 KX TDA600BX ...
Page 48: ...10 1 2 2 Noise is created 48 KX TDA600BX ...
Page 49: ...10 1 3 Paging 10 1 3 1 The path cannot connect 10 1 3 2 Noise is created 49 KX TDA600BX ...
Page 50: ...50 KX TDA600BX ...
Page 51: ...51 KX TDA600BX ...
Page 52: ...10 1 4 Using MOH 52 KX TDA600BX ...
Page 53: ...53 KX TDA600BX ...
Page 54: ...54 KX TDA600BX ...
Page 55: ...10 1 5 USB 10 1 5 1 USB Connection 55 KX TDA600BX ...
Page 56: ...56 KX TDA600BX ...
Page 57: ...10 1 6 RS 232C 10 1 6 1 RS 232C Connection 57 KX TDA600BX ...
Page 58: ...58 KX TDA600BX ...
Page 59: ...10 1 7 SD Card IF 59 KX TDA600BX ...
Page 60: ...10 1 8 Other 60 KX TDA600BX ...
Page 61: ...61 KX TDA600BX ...
Page 68: ...2 Pair Port Test operation Select card for Test 3 Click Pair Port Test 68 KX TDA600BX ...
Page 69: ...4 Test OK 5 Click Cancel 69 KX TDA600BX ...
Page 70: ...6 Card Test operation Select card for Test 7 Click Card Test 70 KX TDA600BX ...
Page 71: ...8 Click Test 9 Click Cancel 71 KX TDA600BX ...
Page 81: ...13 TERMINAL GUIDE OF ICS TRANSISTORS AND DIODES 81 KX TDA600BX ...
Page 83: ...15 CABINET AND ELECTRICAL PARTS LOCATION 83 KX TDA600BX ...
Page 84: ...15 1 EXTENSION BOARDS FOR SERVICING 84 KX TDA600BX ...
Page 85: ...16 ACCESSORIES AND PACKING MATERIALS 85 KX TDA600BX ...
Page 95: ...18 1 WAVEFORM 95 KX TDA600BX ...
Page 96: ...96 KX TDA600BX ...
Page 97: ...18 2 EMPR BLOCK DIAGRAM 97 KX TDA600BX ...
Page 129: ...19 11 MEMO 129 KX TDA600BX ...