12 CHECK PROCEDURE (BASE UNIT)
12.1. Preparation
12.1.1. Equipment Required
·
DECT tester: Rohde & Schwarz, CMD 60 is recommended.
·
Frequency counter: it must be precise to be able to measure 1Hz (precision; ± 4ppm).
Hewlett Packard, 53131A is recommended.
·
DC power: it must be able to output at least 1A current under 9V.
·
Digital multi-meter (DMM): it must be able to measure voltage and current.
·
Oscilloscope
12.1.2. JIG and PC
·
EEPROM serial JIG
JIG Cable: PQZZ1CD505E
·
PC which runs in DOS mode
·
Batch file for setting: PQZZTCD510RU
12.2. PC Setting
12.2.1. Connections
12.2.2. PC Setting
1. Open a window of MS-DOS mode from the start-up menu.
2. Change a directory.
3. Type “SET_COM 1” from the keyboard (when COM port 1 is used for the connection).
4. Type “doskey”.
Note:
See the table below for frequently used commands.
Command name
Function
Example
rdeeprom
Read the data of EEPROM
Type “rdeeprom 00 00 FF”, and the data from
address “00 00” to “FF” is read out.
readid
Read ID (RFPI)
Type “readid”, and the registered ID is read out.
writeid
Write ID (RFPI)
Type “writeid 00 18 E0 0E 98”, and the ID “0018 E0 0E
98” is written.
setfreq
adjust Frequency of RFIC
Type “setfreq nn”.
hookoff
off-hook mode on Base
Type “hookoff”.
hookon
on-hook mode on Base
Type “hookon”.
Getchk
Read checksum
Type “getchk”.
Wreeprom
write eeprom
Type "wreeprom 01 23 45". "01 23" is address and "45"
is data to be written.
51
KX-TCD510RUM / KX-TCD510R UT / KX-TCD510R UV / KX-TCD512R UM / KX-TCD512R UT / KX-TCD512RUV
Summary of Contents for KX-TCD510RUM
Page 11: ...11 KX TCD510RUM KX TCD510RUT KX TCD510RUV KX TCD512RUM KX TCD512RUT KX TCD512RUV ...
Page 30: ...30 KX TCD510RUM KX TCD510RUT KX TCD510RUV KX TCD512RUM KX TCD512RUT KX TCD512RUV ...
Page 37: ...37 KX TCD510RUM KX TCD510RUT KX TCD510RUV KX TCD512RUM KX TCD512RUT KX TCD512RUV ...
Page 100: ...37 1 Memo 100 KX TCD510RUM KX TCD510RUT KX TCD510RUV KX TCD512RUM KX TCD512RUT KX TCD512RUV ...