Address
Default
Name
Type
Description
0F04
9A
LowVoltage
A
Voltage on which to start battery low-
indication.
The voltage has to be measured under this
value for
8 seconds before the handset start
signaling low battery.
LowVoltage[eeprom]=[ADC-steps]=
LowVoltage[mV](14.35[mV/step])
28.3.4. Default Audio-Parameters
Address
Default
Name
Country
Setting
Type
Description
0F36
46
GR-offset for
volumestep 1
x
D
Bit7: AOG
Bit6: AOG2
Bit5, bit0: Gain-receive (values ranging
from 0x00 to 0x30, each step representing
1 dB)
0F37
5F
GR-offset for
volumestep 2
x
A
Bit7: AOG
Bit6: AOG2
Bit5, bit0: Gain-receive (values ranging
from 0x00 to 0x30, each step representing
1 dB)
0F38
46
GR-offset for
volumestep 3
00
D
Bit7: AOG
Bit6: AOG2
Bit5, bit0: Gain-receive offset to
volumestep 2 (values ranging from 0x00
0x30, each step representing 1 dB)
0F3F
02
EEVoiceVolume
x
D
Volume of the earpiece
28.3.5. VolumeSetting Second Block
79
www.freeservicemanuals.info
1/2/2015
Digitized in Heiloo, Holland