![Panasonic KX-TCA121EXT Service Manual Download Page 62](http://html.mh-extra.com/html/panasonic/kx-tca121ext/kx-tca121ext_service-manual_263501062.webp)
Items
Check
Point
Procedure
Check or
Replace Parts
(L)*
Modulation Check and
Adjustment
-
Follow steps 1 to 3 of (K) above.
4.Confirm that the B-Field Modulation is -350 ~ -400/+320 ~ +370kHz/div using
data type Fig 31.
5.Adjust the B-Field Modulation if required. (Execute the command “Readmod”
and “wrtmod xx”, where xx is the value.)
IC1, R54, C62,
C123, C60,
C63, C45,
C44, C47,
C46, C49,
C48, C50,
C53, C51,
R59, C54,
C55, CN6
(M)
Frequency Offset
Confirmation
-
Follow steps 1 to 3 of (K) above.
4.Confirm that the frequency Offset is < ± 45kHz.
IC1, R54, C62,
C123, C60,
C63, C45,
C44, C47,
C46, C49,
C48, C50,
C53, C51,
R59, C54,
C55, CN6
(N)
Frequency Drift
Confirmation
-
Follow steps 1 to 3 of (K).
4.Confirm that the frequency Drift is < ± 30kHz/ms.
IC1, R54, C62,
C123, C60,
C63, C45,
C44, C47,
C46, C49,
C48, C50,
C53, C51,
R59, C54,
C55, CN6
(O)
Sensitivity Receiver
Confirmation
-
Follow steps 1 to 3 of (K).
4.Set DECT tester power to -88dBm.
5.Confirm that the BER is < 1000ppm.
IC1, R54, C62,
C123, C60,
C63, C45,
C44, C47,
C46, C49,
C48, C50,
C53, C51,
R59, C54,
C55, CN6
(P)
Timing Confirmation
-
Follow steps 1 to 3 of (K).
4.Confirm that the Timing accuracy is < ± 2.0ppm.
IC1, R54, C62,
C123, C60,
C63, C45,
C44, C47,
C46, C49,
C48, C50,
C53, C51,
R59, C54,
C55, CN6
(Q)*
RSSI Level
Confirmation
-
Follow steps 1 to 3 of (K).
4.Set DECT tester power to -81dBm.
5.Execute the command “readrssi“.
6.Confirm that the returned value is 0×1C ± 8 (hex).
7.Set DECT tester power to -63dBm.
8.Execute the command “readrssi“.
9.Confirm that the returned value is 0×25 ± 8 (hex).
IC1, R54, C62,
C123, C60,
C63, C45,
C44, C47,
C46, C49,
C48, C50,
C53, C51,
R59, C54,
C55, CN6
(R)
Power RAMP
Confirmation
-
Follow steps 1 to 3 of (K).
4.Confirm that Power RAMP is matching.
IC1, R54, C62,
C123, C60,
C63, C45,
C44, C47,
C46, C49,
C48, C50,
C53, C51,
R59, C54,
C55, CN6
(S)
Audio Check and
Confirmation
-
1.
Link to BASE which is connected to Line Simulator.
2.
Set line voltage to 48V and line current to 40mA.
3.
Input -45dBm/1KHz to MIC and measure Line output level.
4.
Confirm that the level is -7.5dBm ± 2dBm and that the distortion level is < 5%
at TEL Line (600
Ω
Load).
5.
Input -20dBm/1KHz to Line I/F and measure Receiving level at REV1 and
REV2.
6.
Confirm that the level is -20.5dBm ± 2dBm and that the distortion level is < 5%
at Receiver. (vol = 2)
IC1, C37, C68,
C91, R25,
R26, C20,
C12, C87,
C109, R85,
C103, C10,
C17, R86,
R29, R37,
R38, D4, D5,
C69, C70, C95
62
KX-TCD220SLT / KX-TCA122EXT / KX-TCA121EXT
Summary of Contents for KX-TCA121EXT
Page 23: ...23 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Page 29: ...9 2 Available Character Entries for SMS 29 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Page 35: ...10 4 Using Direct Commands 35 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Page 43: ...13 HOW TO REPLACE THE HANDSET LCD 43 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Page 47: ...14 3 Check Link 14 3 1 Base Unit 47 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Page 49: ...14 3 2 Handset 49 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Page 77: ...26 SIGNAL ROUTE 77 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Page 78: ...78 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...