background image

10

Note

: The Doorphone can be installed directly into a wall recess without

using the interface bracket. Use the mounting template on page 15 for
drilling positions. Use the supplied 25 mm (1") screws to fix to the wall
(see Figure 11).

Figure 10

Figure 11

5. Feed the wires through the center of the interface bracket and

connect the wires to the Doorphone Module.

6. Attach the front of the Doorphone to the bracket using the supplied

10 mm ( / ") M3 threaded screws.

3 8

8

1

Note

: To ensure the correct fitting of the Doorphone, please do not allow

the screw head to protrude more than 3mm ( / ") beyond the interface
bracket.

Summary of Contents for KX-T7775

Page 1: ...Doorphone Please read before using the unit and save for future reference KX T7775 Operating Instructions Model No ...

Page 2: ... TA1232 KX TA624 KX TA308 KX TD816 KX TD1232 KX TDA50 KX TDA100 KX TDA200 KX TAW848 KX TA824 KX TD500 KX T30810 KX T61610 and KX T123211 Notes 1 The KX T7775 Doorphone is not compatible with KX TD308 and KX T336 PBX systems 2 The KX T7775 Doorphone cannot be used with a metal gang box Accessory Order Information Replacement parts and accessories are available through your local authorized parts di...

Page 3: ... V Terminal Block Output Door 1 to KX T7775 Doorphone Terminal Block Input Door 1 Terminal Block Output Doorbell In Doorbell Out Dimensions H x W x D 130 mm x 85 mm x 51 mm 5 x 3 x 2 Weight 0 4 kg 0 89 lb Note Specifications are subject to change Location Exposure to direct sunlight can result in the discoloration of the Doorphone Unit The Doorphone Unit can be mounted externally and is weather re...

Page 4: ...ssible it should share any power failure backup systems provided for the PBX A maximum distance of no more than 10 m 32 ft is advised 2 Figures 2 and 3 on page 5 show interconnection in more detail 3 The connection between the Doorphone and the Power Module is not polarity sensitive 4 Inputs to the bell contacts must not exceed 24 V AC 5 This Doorphone manual should be read in conjunction with the...

Page 5: ...UT DOORPHONE MODULE POWER MODULE Figure 2 Doorphone Module s Interconnects AC ADAPTOR Max 500 m 1640 ft 22 AWG DOOR 1 POWER MODULE MODULAR JACK 2 3 4 5 PBX DOORPHONE CARD AC ADAPTOR Figure 3 Power Module s Interconnects Note Polarity sensitive Refer to pages 6 to 8 for pin details ...

Page 6: ...AB UPWARDS MODULAR JACK Note Power Module 2 is not available with KX TA308 KX T30810 KX T61610 KX T123211 Figure 5 KX TD500 Connection Details MODULAR JACK PBX DOORPHONE CARD PQJS1T30ZA E 1 3 5 2 4 6 2 3 4 5 KX TD500 2 3 4 5 NOT USED NOT USED NOT USED NOT USED TAB UPWARDS TAB UPWARDS MODULAR PLUG POWER MODULE 1 POWER MODULE 2 MODULAR JACK MODULAR PLUG MODULAR JACK Figure 4 KX TD816 KX TD1232 KX TA...

Page 7: ...etails KX TD816 KX TD1232 KX TA1232 using KX TD160 DP Interface and KX TA824 KX TAW848 KX TDA50 MODULAR JACK PBX DOORPHONE CARD PQJS1T30ZA E 1 3 5 2 4 6 23 4 5 2 3 4 5 NOT USED NOT USED NOT USED NOT USED MODULAR PLUG TAB UPWARDS POWER MODULE 1 POWER MODULE 2 MODULAR JACK MODULAR PLUG TAB UPWARDS MODULAR JACK 7 ...

Page 8: ...ection Details 3 4 KX TDA100 200 5 2 NOT USED NOT USED 3 4 5 2 3 4 5 2 3 4 5 2 NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED MODULAR PLUG TAB UPWARDS POWER MODULE 1 MODULAR JACK POWER MODULE 2 POWER MODULE 3 POWER MODULE 4 ...

Page 9: ...front panel to the back unit using the supplied 10 mm M3 threaded screws To flush mount the Panasonic KX T7775 Doorphone 1 Separate the Doorphone Unit into two halves Discard the rear section of the Unit 2 Adjust the sensitivity of the Doorphone s microphone if required see page 11 3 Attach the gasket to the rear of the interface bracket as shown in Figure 8 The gasket side faces the wall 4 Gang b...

Page 10: ...ix to the wall see Figure 11 Figure 10 Figure 11 5 Feed the wires through the center of the interface bracket and connect the wires to the Doorphone Module 6 Attach the front of the Doorphone to the bracket using the supplied 10 mm M3 threaded screws 3 8 8 1 Note To ensure the correct fitting of the Doorphone please do not allow the screw head to protrude more than 3mm beyond the interface bracket...

Page 11: ...Insert flat headed screwdriver here Locate the switch Turn the switch clockwise if sited in a noisy location Turn the switch counter clockwise for normal noise level factory setting Operation Calling from doorphone 1 Press the call button see Figure 12 The caller hears confirmation tone 2 Wait for answer Talk Calling from an extension 1 Pick up your handset 2 Dial the Doorphone s extension number ...

Page 12: ... for ventilation to protect it from overheating these openings must not be blocked or covered The openings should never be blocked by placing the product on a bed sofa rug or other similar surface This product should never be placed near or over a radiator or other heat source This product should not be placed in a built in installation unless proper ventilation is provided This product should be ...

Page 13: ...icing to qualified service personnel under the following conditions When the power supply cord or plug is damaged or frayed If liquid has been spilled into the product If the product does not operate normally by following the operating instructions Adjust only those controls that are covered by the operating instructions because improper adjustment of other controls may result in damage and will o...

Page 14: ...be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet or a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio T...

Page 15: ...concrete or mortar wall fit anchor plugs not included into the wall with a hammer beforehand DRILL HOLES HERE WHEN ATTACHING INTERFACE BRACKET TO WALL DRILL HOLE HERE IF ATTACHING FRONT OF UNIT DIRECTLY TO WALL DRILL HOLE HERE IF ATTACHING FRONT OF UNIT DIRECTLY TO WALL Wall Mounting Template 116 mm 4 16 9 ...

Page 16: ...e reference Note The serial number of this product can be found on the label affixed to the unit You should record the model number and the serial number of this unit as a permanent record of your purchase to aid in identification in the event of theft Model No KX T7775 Serial No Date of Purchase Name of dealer Dealer s address Dealer s Tel No QUQX00152WA KU0505SC0 Printed in the United Kingdom Wh...