4. Remove the Connector from the Main Board.
5. Remove 2 Screws (A).
6. Remove the Main Board and the LCD from the
Cabinet Body.
7. HOW TO REPLACE A FLAT PACKAGE IC
7.1. PREPARATION
- PbF (: Pb free) Solder
- Soldering Iron
Tip Temperature of 700°F ± 20°F (370°C ± 10°C)
Note: We recommend a 30 to 40 Watt soldering iron. An expert
may be able to use a 60 to 80 Watt iron where someone with less
experience could overheat and damage the PCB foil.
- Flux
Recommended Flux: Specific Gravity 0.82.
Type RMA (lower residue, non-cleaning type)
Note: See
ABOUT LEAD FREE SOLDER (PbF: Pb free)
().
7.2. PROCEDURE
1. Tack the flat pack IC to the PCB by temporarily soldering two
diagonally opposite pins in the correct positions on the PCB.
7
Summary of Contents for KX-T7665NE
Page 4: ...4 ...
Page 6: ...1 Remove the Stand 2 Remove 5 Screws A 3 Remove the Cabinet Cover 6 ...
Page 9: ...8 1 NO OPERATION Note Refer to 1 4 of WAVEFORM for waveform 8 2 LCD DOES NOT OPERATE 9 ...
Page 10: ...Note Refer to 5 of WAVEFORM for waveform 8 3 HANDSET DOES NOT WORK Receive Send 10 ...
Page 11: ...Note Refer to 6 7 of WAVEFORM for waveform 8 4 SPEAKER PHONE TROUBLE Receive Send 11 ...
Page 14: ...LCD Contrast Control CONTRAST IC6 Pin 59 IC6 Pin19 HIGH L L MIDDLE Z L LOW Z Z 14 ...
Page 26: ...13 CABINET AND ELECTRICAL PARTS LOCATION 26 ...
Page 27: ...14 ACCESSORIES AND PACKING MATERIALS 27 ...
Page 28: ...28 ...