59
KX-PRW120W/KX-PRWA10W
11.6.1.2. Handset
First, operate the PC setting according to
The Setting Method of JIG (Handset)(
P.55).
Then download the appropriate data according to the following procedures.
Note:
(*3) WW: country code, XXX_YYY: revision number
“XXX_YYY” vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in
The Setting
Method of JIG (Handset)
(P.55).
(*4) Refer to
Check Point (Handset)
(P.43)
Items
How to download/Required adjustment
FLASH(IC2)
Programming data is stored in memory.
1)Execute ComCommunicator.exe in the ComCommunicator
folder.
2) Initialize COM port. (Only once at first.)
3) Select serial port COM number. (Only once at first.)
4) Select ProgramLoader ( アドオン /ProgramLoader)
5) Select "Setting"/"Config"
6) Select download file
7) Start download.
(a)Connect Unit and 3 wire jig.
(b)Confirm "Turn on power to target and press download."
display.
(c)Power off the unit, then power on.
(d)Press Download button again.
8) Finish download
Completed dialog means "Successfully download." (It takes
more than 1 hours to download.)
If error message is displayed, proceed from step 6 again.
9) Detach the JIG cable again,and execute POWER OFF/ON.
10) Connect the JIG cable again,and execute the command
"getchk",then confirm the checksum value is correct.
(if the downloading falls,start again from step 6)
11) Default batch file:Exexute the command "default.bat".
12) Default batch file:Exexute the command
"PRWA10US_DEF_RevXXX_YYY.bat".(*3)
13) Country version batch file:Exexute the command
"PRWA10US_WW_RevXXX_YYY.bat"..(*3)
14) Clock adjustment: Refer to Check Point(H).(*4)
Note:
Refer to the file named "OI manual for BBIC update - for
TBR(Handset).xls".
EEPROM (IC3)
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
1) Change the address “0001” of EEPROM to “00” to download
the data.
2) Default batch file: Execute the command “default.bat”.
3) Default batch file (remaining): Execute the command
“PRWA10US_DEF_RevXXX_YYY.bat”. (*3)
4) Country version batch file: Execute the command
“PRWA10US_WW_RevXXX_YYY.bat”. (*3)
5) Clock adjustment: Refer to Check Point (H). (*4)
6) 1.8 V setting and battery low detection: Refer to Check Point
(A), (F) and (G). (*4)
X'tal (X1)
System clock
Clock adjustment data is in EEPROM, adjust the data again
after replacing it.
1) Refer to Check Point (C). (*4)