background image

Installation Manual

E1 Trunk Adaptor/PRI Adaptor

Thank you for purchasing this Panasonic product.
Please read this manual carefully before using this product and save this manual for future use.

Compatible PBX:
KX-NS1000 PCMPR Software File Version 002.00000 or later

Model No.  

KX-NS8188
KX-NS8290

Summary of Contents for KX-NS8290

Page 1: ...r Thank you for purchasing this Panasonic product Please read this manual carefully before using this product and save this manual for future use Compatible PBX KX NS1000 PCMPR Software File Version 0...

Page 2: ...re version of your PBX The contents of this manual apply to PBXs with a certain software version as indicated on the cover of this manual Please confirm the software version of your PBX You can connec...

Page 3: ...allation of the Trunk Adaptor 25 3 2 1 Unpacking 25 3 2 2 Names and Locations 25 3 2 3 LED Indications 26 3 2 4 Types of Connectors 27 3 2 5 Placing the Trunk Adaptor on a Desktop 27 3 2 6 Wall Mounti...

Page 4: ...4 Installation Manual Table of Contents...

Page 5: ...Section 1 Safety Precautions This section provides important information intended to prevent personal injury and property damage Installation Manual 5...

Page 6: ...could result in death or serious injury CAUTION This notice means that misuse could result in injury or damage to property The following types of symbols are used to classify and describe the type of...

Page 7: ...ee burns Do not make power connections that exceed the ratings for the AC outlet or power equipment If the power rating is exceeded it can cause a fire due to heat buildup Care should be taken so that...

Page 8: ...le or cord If the power is supplied from the network to the Trunk Adaptor Power over Ethernet disconnect the Ethernet cables Otherwise disconnect the AC adaptor cord Then return the Trunk Adaptor to a...

Page 9: ...rature more than 40 C low temperature less than 0 C and vibration and should not be exposed to direct sunlight Before touching the product discharge static electricity by touching ground or wearing an...

Page 10: ...period of time disconnect the Trunk Adaptor from the AC outlet When the Trunk Adaptor receives power from a PoE power supply disconnect the LAN cable To ensure the security of private conversations o...

Page 11: ...for this Trunk Adaptor or the PBX If the problem is not resolved consult your dealer SECURITY REQUIREMENTS Keep a copy of all important data such as your network information before sending the machin...

Page 12: ...ric shock from lightning Do not use a telephone in the vicinity of a gas leak to report the leak Rack Mount Instructions The following or similar rack mount instructions are included with the installa...

Page 13: ...ask for the correct method of disposal Note for the battery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the require...

Page 14: ...cal calling area The zero area code should either be removed when calling back local numbers or check with your toll carrier that a charge will not be levied All persons using this device for recordin...

Page 15: ...Internet activate a Firewall 2 To avoid unauthorised access and possible abuse of the Trunk Adaptor we strongly recommend a Keeping the password secret b Selecting a complex random password that canno...

Page 16: ...ith Canadian ICES 003 Notice Attachment of non IC certified registered equipment is illegal in some areas of Canada Please consult your Telephone Company CAUTION Users should not attempt to make such...

Page 17: ...Section 2 System Outline This section provides general information on the Trunk Adaptor including the system capacity and specifications Installation Manual 17...

Page 18: ...06CE KX A239EJ PQLV206E KX A239UK PQLV206E KX A239X PQLV206 KX A420BR PSLP1662 Note To order an optional AC adaptor please order using the KX A239xx KX A420BR model number not PQLV206xx PSLP1662 For u...

Page 19: ...ion keys Pure IP PBX KX NS1000 SIP Phone KX UT series IP PT KX NT series PC Web Maintenance Console Telephone Company LAN E1 PRI 23 ch 30 ch E1 Trunk Adaptor KX NS8188 PRI Adaptor KX NS8290 DSU 1 1 DS...

Page 20: ...features supported by the E1 Trunk Adaptor Note that the private network feature is not available Features Signalling DR2 Dial type MFC R2 DTMF Incoming call Outgoing call Caller Number Notification A...

Page 21: ...SDN QSIG ISDN QSIG H 323 H 323 Private Mode DSU DSU The following table shows features supported by the PRI Adaptor Features Mode CO QSIG Master Slave Incoming call Outgoing call ISDN carrier service...

Page 22: ...Loop back mode Local loop back Remote loop back System Initialise switch Push switch non latching Power consumption PoE Maximum 6 4 W AC adaptor Maximum 6 75 W Power over Ethernet IEEE 802 3af Class 2...

Page 23: ...Section 3 Installation This section describes the procedures to connect the Trunk Adaptor to the PBX Installation Manual 23...

Page 24: ...tall the system in the following locations In direct sunlight and hot cold or humid places Temperature range 0 C to 40 C Areas where sulphuric gases may be present such as near thermal springs Near de...

Page 25: ...ppropriately 3 2 2 Names and Locations Back Side Front Side when Wall Mounted Front Side A B C DE F H G No Name Description A SYSTEM LED System operating status indication B LINE LED Alarm synchronisa...

Page 26: ...up Slow Green Flashing Running In Service Green On System initialisation failed Quick Red Flashing Malfunction occurring Fault Red On Halting operation Out of Service Amber On Shutting down Slow Amber...

Page 27: ...t is placed as indicated in the diagram below Do not place it on its side or upside down Desk or Table When placing the Trunk Adaptor on a desktop be sure to run the cables on the side of the Trunk Ad...

Page 28: ...or other heat source Do not bundle cables that are connected to the Trunk Adaptor with the AC power cords of machines located nearby Make sure the cables are securely fastened to the wall When mounti...

Page 29: ...3 Hook the Trunk Adaptor on the screw heads in any of the following 4 directions Washer Drive the screw to this point A B C D Hook this part onto both screws Installation Manual 29 3 2 6 Wall Mounting...

Page 30: ...size to correspond with the size of this page If the dimension of the paper output still deviates slightly from the measurement indicated here use the measurement indicated here 3 2 7 Wiring Requireme...

Page 31: ...the Trunk adaptor s IP address from the network manager 2 Connect a PC to the Trunk Adaptor with a LAN cable See 4 2 PC Connection 3 Connect an AC adaptor to the Trunk Adaptor ensuring that it is hook...

Page 32: ...LED Indications Note If connecting to the KX NS1000 via SIP confirm that the SIP trunk port status is INS through the KX NS1000 s Web Maintenance Console SIP connection and registration is possible on...

Page 33: ...ion 4 Programming with Web Maintenance Console This section describes the installation procedure structure and functions of Web Maintenance Console for programming the Trunk Adaptor Installation Manua...

Page 34: ...For details about the KX NS1000 Web Maintenance Console refer to Overview of Web Maintenance Console in the Installation Manual of the KX NS1000 PBX The settings on the screen are as follows Setting I...

Page 35: ...Setting Item Description Value Range Software Version Displays the Trunk Adaptor s software version 000 000 00 999 999 99 Installation Manual 35 4 1 Overview of Web Maintenance Console...

Page 36: ...to the PC For information about fixed IP addresses ask your network administrator Note Use an Ethernet cable with an RJ45 connector to connect a PC to the Trunk Adaptor The pin assignments and maximum...

Page 37: ...AC Adaptor Switching Hub LAN System Initialise Switch LAN Port PC Router Router Internet CAUTION It is strongly recommended to use SSL encrypted communication when the PC is accessing the Trunk Adapto...

Page 38: ...A Data Security Inc Created 1991 All rights reserved Licence to copy and use this software is granted provided that it is identified as the RSA Data Security Inc MD5 Message Digest Algorithm in all ma...

Page 39: ...r the PBX you are connecting to c KX NS8290 only Select a Network Type from the drop down list Public or Private d Specify SIP Authentication ID Plan which is the header digits of the SIP authenticati...

Page 40: ...to restart the Trunk Adaptor Otherwise the login screen will be displayed 8 Log in using the password entered during Easy Setup Wizard The home screen is displayed You may now begin programming the T...

Page 41: ...n Option Mandatory No Transmission Status Receive Ignore Disconnect Ignore CRC4 Mode Disable Enable Enable Line Coding B8ZS AMI B8ZS Frame Sequence Extend Multi frame ESF 4 Frame Multi frame F4 12 Fra...

Page 42: ...umber Numbering Plan ID Public Unknown ISDN Telephony National Standard Private Unknown Calling Party Number Numbering Plan ID Private Unknown ISDN Telephony National Standard Private Private Calling...

Page 43: ...sable Calling Party Name Presentation to PRI23 Enable Disable Disable Calling Party Name Sending Format Display Facility Display PRI23 PRI30 Port Property Supplementary Service Displayed only when Net...

Page 44: ...711A Incoming Call Inter digit Timer DDI DID 0 30 s 5 s E1 Card Property Line Signal Setting DR2 Setting Type Normal Option 1 Option 3 Normal Inter digit Timer 3 15 s 4 s Bit Position for Dial Flash A...

Page 45: ...Complete 2 Undefined 1 15 Undefined Group l Code Assignment ANI Complete 3 Undefined 1 15 Undefined Group l Code Assignment ANI Complete 4 Undefined 1 15 Undefined Group l Code Assignment ANI Reject...

Page 46: ...nment Set up Speech Path Undefined 1 15 6 Group A Code Assignment First Request Undefined 1 15 Undefined Group A Code Assignment N Request Undefined 1 15 Undefined Group A Code Assignment N 1 Request...

Page 47: ...defined Undefined Receive Digits 0 15 3 CPC Detection Time Out None 80 n n 2 75 ms 160 ms CPC Detection Time In None 80 n n 2 75 ms 80 ms DTMF Width 80 ms 160 ms 80 ms Ringback Tone to Outside Caller...

Page 48: ...Time for G 711A 20 ms 30 ms 40 ms 50 ms 60 ms 20 ms Packet Sampling Time for G 711Mu 20 ms 30 ms 40 ms 50 ms 60 ms 20 ms Packet Sampling Time for G 729A 20 ms 30 ms 40 ms 50 ms 60 ms 20 ms FAX Detecti...

Page 49: ...50 ms Jitter Buffer Delay Max for FAX 10 n n 0 20 ms 50 ms Jitter Buffer Delay Init for FAX 10 n n 0 20 ms 50 ms Jitter Buffer Adaptation Period for FAX 10 n n 100 6553 ms 1800 ms DTMF Detection Leve...

Page 50: ...stored Bandwidth to gatekeeper 1 255 kbps 10 Primary Gatekeeper IP Address 1 0 0 0 223 255 255 255 192 168 1 3 Primary Gatekeeper Port Number 1 65535 1719 Secondary Gatekeeper IP Address 1 0 0 0 223 2...

Page 51: ...3600 50 SIP Location Hold Time Interval 1 10 s 1 s SIP Session Timer Min 90 3600 90 SIP Port Property Port KX NS8290X 1 23 KX NS8188X KX NS8290CE 1 30 Authentication ID 3 5 digits KX NS8290X 401 423...

Page 52: ...t Saving Daylight Saving Automatic Time Adjustment Disable SNTP Disable SNTP IP Address 1 0 0 0 223 255 255 255 SNTP Port Number 123 fixed 123 Time Zone HH 14 14 0 Time Zone MM 00 59 0 Daylight Saving...

Page 53: ...P address IP Address 1 0 0 0 223 255 255 255 192 168 0 151 MAC Address 00 00 00 00 00 00 FF FF FF FF FF FF Set in factory defaults Subnet Mask 0 255 0 255 0 255 0 255 Except 0 0 0 0 and 255 255 255 25...

Page 54: ...255 255 255 IP address Ports Port Number Voice RTP UDP Port No 1024 64000 12000 UDP Port No for SIP Server 1024 65535 5060 LOGIN Port Number 1024 65535 33321 H 225 Port Number 1024 65535 1720 RAS Port...

Page 55: ...on 1 5 Server Port number 21 990 1024 65535 21 Connection 1 5 User name Max 24 characters First character a z after first character a z 0 9 _ or final character is also available Connection 1 5 Passwo...

Page 56: ...Skip depending on whether you want to back up system data before resetting System Control System Shutdown This feature allows you to shutdown the system Click Backup or Skip depending on whether you...

Page 57: ...Collects protocol trace data from the V IPGW16 card Monitor Trace E1 Signalling Bit Monitor Displays reference signalling bit information for the E1 card Monitor Trace E1 Line Trace Traces the sent an...

Page 58: ...roperty Virtual SIP Gateway Main Connection Attribute SIP Provider Trunk Adaptor Select Trunk Adaptor Port Property Virtual SIP Gateway Main Trunk Adaptor List Trunk Adaptor List 16 entries Trunk Adap...

Page 59: ...perty Virtual SIP Gateway Calling Party From Header User Part User Name Authentication ID PBX CLIP Select PBX CLIP DDI DID PBX Configuration 10 2 CO Incoming Call DIL Table Port Settings Category Sett...

Page 60: ...60 Installation Manual 4 5 Programming for the KX NS1000...

Page 61: ...Section 5 Troubleshooting This section provides information on the Trunk Adaptor troubleshooting Installation Manual 61...

Page 62: ...address within the valid range The IP address of the Trunk Adaptor for networking has been forgotten Consult your dealer 5 2 Error Messages Error Message Description Digital trunk out of Synchronizat...

Page 63: ...Index Installation Manual 63...

Page 64: ...Maintenance Console 40 SIP GW Programming for the KX NS1000 58 Specifications General Description 22 Specifications System Capacity 22 Starting the Trunk Adaptor 31 Starting Web Maintenance Console 38...

Page 65: ...th the essential requirements and other relevant provisions of Radio Telecommunications Terminal Equipment R TTE Directive 1999 5 EC Declarations of Conformity for the relevant Panasonic products desc...

Page 66: ...tem Networks Co Ltd 2012 DD0912HK0 v0 007 For Future Reference Please print record and retain the following information for future reference The serial number of this product can be found on the label...