4.11. Protection Circuit
This section describes the Overvoltage Protection Circuit and Overheat Protection Circuit.
1) Abnormal Condition Detection Circuit
Abnormal condition detection circuit is a thyristor circuit which is comprised of Q306 and Q307. When power supply operation
becomes abnormal, a signal is sent to the abnormal detection circuit and Q307 is turned ON. A current flows through the diode
of PC50, which is sent to the control circuit of main converter. The operation of main converter is then stopped.
2) Overheat Detection Circuit
When internal temperature of power supply rises abnormally, resistance values of PTC thermistor PT301 increase, transistor
Q305 turns ON, and signal is sent to the abnormal detection circuit through D312.
3) Overvoltage Protection Circuit
When 15V or 41V output becomes abnormal, that voltage is sent to the abnormal detection circuit through zener diode D311
4) Reverse Connection Protection Circuit
When the battery is connected in reverse, + terminal of the battery becomes negative voltage, D167, D168, D169 start to con-
duct and transistor Q313 turns ON.
Dropper Circuit voltage (in section 5) is sent to the abnormal detection circuit through zener diode D319.
Summary of Contents for KX-NS500AG
Page 21: ...21 KX NS500AG 5 Location of Controls and Components 5 1 Name and Locations ...
Page 24: ...24 KX NS500AG 9 1 1 Startup ...
Page 25: ...25 KX NS500AG ...
Page 26: ...26 KX NS500AG ...
Page 27: ...27 KX NS500AG ...
Page 28: ...28 KX NS500AG 9 1 2 Battery Alarm ...
Page 29: ...29 KX NS500AG 9 1 3 Using Voice Mail ...
Page 30: ...30 KX NS500AG Using Voice Mail continued ...
Page 34: ...34 KX NS500AG 9 2 3 41V are Not Output Only 15V is output ...
Page 35: ...35 KX NS500AG 9 2 4 Battery Backup Function Does Not Operate PSU can Not Charge Batteries ...
Page 43: ...43 KX NS500AG 11 3 3 Power Supply Board ...
Page 59: ...59 KX NS500AG 12 2 Memo ...
Page 73: ...73 KX NS500AG 12 5 Memo ...
Page 131: ...131 KX NS500AG 16 Appendix ...