19
KX-NS500AG
4.10. Alarm Signal Sending Circuit
This section describes the operation of the circuit that sends the AC alarm/DC alarm signal
1) Alarm Circuit Power Supply
This power supply consists mainly of Q301, D301. The output of the main converter (described in section 2) drops from 41V to
around 26V for a more stable supply.
2) AC alarm signal sending circuit
When the AC Detection Circuit (described in section 1 (5)) detects AC input as "Yes", the Secondary side transistor of PC80
turns ON. This action turns Q312 ON and then a LOW signal is sent to AC alarm output.
However, if the AC input is detected as "No", the Secondary side transistor of PC80 turns OFF. This action turns Q312 OFF and
then AC alarm sending output becomes OPEN. (Open collector output)
3) DC Alarm Signal Sending Circuit
When 41V is output normally, transistors Q303 and Q304 in the output voltage detection circuit turn ON. Q302 also turns on and
then DC alarm sending output becomes LOW.
When 41V output becomes abnormal, transistors Q303 and Q304 turn OFF, Q302 turns OFF and DC alarm sending output
becomes OPEN. (Open collector output)
Summary of Contents for KX-NS500AG
Page 21: ...21 KX NS500AG 5 Location of Controls and Components 5 1 Name and Locations ...
Page 24: ...24 KX NS500AG 9 1 1 Startup ...
Page 25: ...25 KX NS500AG ...
Page 26: ...26 KX NS500AG ...
Page 27: ...27 KX NS500AG ...
Page 28: ...28 KX NS500AG 9 1 2 Battery Alarm ...
Page 29: ...29 KX NS500AG 9 1 3 Using Voice Mail ...
Page 30: ...30 KX NS500AG Using Voice Mail continued ...
Page 34: ...34 KX NS500AG 9 2 3 41V are Not Output Only 15V is output ...
Page 35: ...35 KX NS500AG 9 2 4 Battery Backup Function Does Not Operate PSU can Not Charge Batteries ...
Page 43: ...43 KX NS500AG 11 3 3 Power Supply Board ...
Page 59: ...59 KX NS500AG 12 2 Memo ...
Page 73: ...73 KX NS500AG 12 5 Memo ...
Page 131: ...131 KX NS500AG 16 Appendix ...