10.4 PBX Configuration—[2-4] System—Week Table
A specific time mode (day, night, lunch, or break) can be selected for operation depending on the time of day.
The time mode can be switched either automatically or manually. Select the desired switching mode from the
Time Service Switching Mode
option.
Time Table numbers correspond to tenant numbers (for example, Tenant 1 uses Time Table 1). Select the
desired Time Table from the
Time Table No.
list.
When in Automatic Switching mode, the time modes of the tenant are switched as programmed in the
corresponding Time Table. Manual switching is possible only from an authorised extension (determined by
COS).
•
To adjust the currently displayed Time Table, click and drag the divisions between two time periods.
•
To programme the time blocks of the currently displayed Time Table, including adding or deleting time
blocks, click
Time Setting
.
10.4.1 PBX Configuration—[2-4] System—Week Table—Time
Setting
The start times of 4 different time blocks can be programmed for each day of the week, for the selected Time
Table, as well as the start and end times of up to 3 break periods.
1. Day/Lunch/Night—Day1 Start, Lunch Start, Day2 Start, Night Start—Setting
Enables the setting of the start time for each time block.
Value Range
Disable, Enable
Maintenance Console Location
10.4.1 PBX Configuration—[2-4] System—Week Table—Time Setting
Feature Guide References
5.1.3 Tenant Service
5.1.4 Time Service
1. Day/Lunch/Night—Day1 Start, Lunch Start, Day2 Start, Night Start—Hour,
Minute
Specifies the start time for each time block. Times can only be set when
1. Day/Lunch/Night—Day1 Start,
Lunch Start, Day2 Start, Night Start—Setting
Enable
.
Value Range
00:00–23:59
Maintenance Console Location
10.4.1 PBX Configuration—[2-4] System—Week Table—Time Setting
454
PC Programming Manual
10.4.1 PBX Configuration—[2-4] System—Week Table—Time Setting
Summary of Contents for KX-NS500
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 142: ...142 PC Programming Manual 7 12 Utility CS Web Connection ...
Page 552: ...552 PC Programming Manual 10 11 2 PBX Configuration 2 11 2 System Audio Gain Card ...
Page 576: ...5 1 2 Group 576 PC Programming Manual 11 4 PBX Configuration 3 4 Group Paging Group ...
Page 758: ...758 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 810: ...810 PC Programming Manual 17 5 PBX Configuration 9 5 Private Network Centralised UM VM Unit ...
Page 828: ...828 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 850: ...850 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 884: ...884 PC Programming Manual 20 1 3 UM Configuration 1 3 Mailbox Settings Auto Configuration ...
Page 976: ...976 PC Programming Manual 26 1 UM Configuration 7 System Security ...
Page 1007: ...Feature Programming References PC Programming Manual 1007 ...