75
KX-MB2085CXW/KX-MB2090CXW
11.1.3. Service Function Table
Code
Function
Set Value
Effective
Range
Default
Remarks
501
Pause time set
X 100 msec
001~600
030
----------
503
Dial speed select
1:10 pps
2:20 pps
1, 2
1
----------
507
V34 transmission start speed
0: Disable
1: 33.6
2: 31.2
3: 28.8
4: 26.4
5: 24.0
6: 21.6
7: 19.2
8: 16.8
0~8
1
If the code 527 is set at 2, the code 507 and 508
work.
508
V34 reception start speed
0: Disable
1: 33.6
2: 31.2
3: 28.8
4: 26.4
5: 24.0
6: 21.6
7: 19.2
8: 16.8
0~8
1
If the code 527 is set at 2, the code 507 and 508
work.
514
Bell signal detect time
X 100msec
1~9
6
----------
520
CED frequency select
1:2100 Hz
2:1100 Hz
1, 2
1
See
How To Output The Journal Report
521
International mode select
1:ON 2:OFF 1, 2
1
See
How To Output The Journal Report
522
Auto standby select
1:ON 2:OFF 1, 2
1
The resolution reverts to the default when transmis-
sion is complete.
523
Receive equalizer select
1: 0 km
2: 1.8 km
3: 3.6 km
4: 7.2 km
1~4
1
Set RX equalizer to automatic mode.
524
Transmission equalizer select
1: 0 km
2: 1.8 km
3: 3.6 km
4: 7.2 km
1~4
1
527
V.8 function select
1:OFF 2:ON 1, 2
2
529
Call Service Clear
550
Memory clear
Refer to
551
ROM check
See
552
DTMF single tone test
1:ON 2:OFF 1, 2
2
See
553
Monitor on FAX communication
select
1:OFF
2:PHASE B
3:ALL
1~3
1
Sets whether to monitor the line signal with the
unit's speaker during FAX communication or not.
554
Modem test
See
555
Scanner test
See
556
Motor test
0
See
557
LED test
See
558
LCD test
See
561
KEY test
See
567
T0 timer
X second
001~255
052
Sets a higher value when the response from the
other party needs more time during automatic FAX
transmission.
570
BREAK % select
1:61% 2:67% 1, 2
1
*1
Sets the % break of pulse dialing according PBX.
571
ITS auto redial time set
X number of
times
00~99
05
Selects the number of times that ITS is redialed
(not including the first dial).
572
ITS auto redial line disconnection
time set
X second
001~999
185
Sets the interval of ITS redialing.
573
Remote turn-on ring number set
X number of
rings
00~99
10
Sets the number of rings before the unit starts to
operate TAM in the TEL mode.
574
Dial tone detect check
1: ON 2: OFF 1, 2
2
----------
590
FAX auto redial time set
X number of
times
00~99
05
Selects the number of redial times during FAX com-
munication (not including the first dial).
591
FAX auto redial time disconnection
time set
X second
001~999
185
Sets the FAX redial interval during FAX communi-
cation.
Summary of Contents for KX-MB2085CXW
Page 44: ...44 KX MB2085CXW KX MB2090CXW 6 11 LSU Laser Scanning Unit Section ...
Page 45: ...45 KX MB2085CXW KX MB2090CXW ...
Page 53: ...53 KX MB2085CXW KX MB2090CXW 6 12 9 2 Drum Detection ...
Page 60: ...60 KX MB2085CXW KX MB2090CXW ...
Page 80: ...80 KX MB2085CXW KX MB2090CXW KX MB2090 ...
Page 81: ...81 KX MB2085CXW KX MB2090CXW Note The above values are the default values ...
Page 112: ...112 KX MB2085CXW KX MB2090CXW 12 3 7 6 Light Print CROSS REFERENCE High Voltage Section P 152 ...
Page 114: ...114 KX MB2085CXW KX MB2090CXW 12 3 8 2 The Recording Paper Is Waved or Wrinkled ...
Page 115: ...115 KX MB2085CXW KX MB2090CXW 12 3 8 3 Skew ...
Page 117: ...117 KX MB2085CXW KX MB2090CXW 12 3 8 5 The Recording Paper Jam ...
Page 126: ...126 KX MB2085CXW KX MB2090CXW ...
Page 128: ...128 KX MB2085CXW KX MB2090CXW ...
Page 129: ...129 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 130: ...130 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 131: ...131 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 132: ...132 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 133: ...133 KX MB2085CXW KX MB2090CXW ...
Page 134: ...134 KX MB2085CXW KX MB2090CXW ...
Page 135: ...135 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 144: ...144 KX MB2085CXW KX MB2090CXW 12 3 15 Motor Section 12 3 15 1 Engine Motor ...
Page 148: ...148 KX MB2085CXW KX MB2090CXW 12 3 17 CIS Control Section ...
Page 149: ...149 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 151: ...151 KX MB2085CXW KX MB2090CXW ...
Page 152: ...152 KX MB2085CXW KX MB2090CXW 12 3 19 High Voltage Section 1 Main ...
Page 153: ...153 KX MB2085CXW KX MB2090CXW 2 CHG GRID ...
Page 154: ...154 KX MB2085CXW KX MB2090CXW 3 TRA ...
Page 155: ...155 KX MB2085CXW KX MB2090CXW 3 DEV DC ...
Page 156: ...156 KX MB2085CXW KX MB2090CXW TRA ...
Page 158: ...158 KX MB2085CXW KX MB2090CXW 2 Confirmation of the main unit ...
Page 160: ...160 KX MB2085CXW KX MB2090CXW Waveform of normal operation ...
Page 162: ...162 KX MB2085CXW KX MB2090CXW 2 When 100Base TX enabled deviced is connected ...
Page 163: ...163 KX MB2085CXW KX MB2090CXW 3 When 10Base T enabled device is connected ...
Page 168: ...168 KX MB2085CXW KX MB2090CXW 12 3 23 2 Troubleshooting Flow Chart ...
Page 171: ...171 KX MB2085CXW KX MB2090CXW 13 Service Fixture Tools ...
Page 173: ...173 KX MB2085CXW KX MB2090CXW 14 1 Bottom Section 14 2 Left Side Section ...
Page 174: ...174 KX MB2085CXW KX MB2090CXW 14 3 Operation Panel Section 14 4 Open Top Cover ...
Page 175: ...175 KX MB2085CXW KX MB2090CXW 14 5 Remove Operation Panel 14 6 Remove Operation Board ...
Page 176: ...176 KX MB2085CXW KX MB2090CXW 14 7 Remove Main Board ...
Page 177: ...177 KX MB2085CXW KX MB2090CXW 14 8 Remove Gear Chassis Section ...
Page 178: ...178 KX MB2085CXW KX MB2090CXW 14 9 Remove Right Cover 14 10 Remove Right Cassette Guide ...
Page 179: ...179 KX MB2085CXW KX MB2090CXW 14 11 Remove Bottom Plate 14 12 Remove Laser Unit ...
Page 180: ...180 KX MB2085CXW KX MB2090CXW 14 13 Remove Pick up Roller ...
Page 181: ...181 KX MB2085CXW KX MB2090CXW 14 14 Remove Low Voltage Power Board 14 15 Remove Mirror ...
Page 200: ...200 KX MB2085CXW KX MB2090CXW 15 6 1 NG Example ...
Page 201: ...201 KX MB2085CXW KX MB2090CXW 15 7 Test Chart 15 7 1 ITU T No 1 Test Chart ...
Page 202: ...202 KX MB2085CXW KX MB2090CXW 15 7 2 ITU T No 2 Test Chart ...
Page 257: ...Information The extract from an Operating Instructions ...