Page 1: ...KX HGT100 SIP Phone Panasonic Telephone Systems www voicesonic com Phone 877 289 2829 Panasonic KX HGT100 KXHGT100 HGT100 CONFIGURATIONS AND USER SETTINGS ...

Page 2: ... Connect the HGT100 to the LAN via a suitable switch port 2 Power on the unit using PoE or the optional AC Adaptor 3 Check the LCD Display shows Not configured Web Setting 4 Using your Browser Internet Explorer etc access http 192 168 0 241 Not Configured Web Setting ...

Page 3: ...KX HGT100 Configuration 2 Unit has no Profile set Registration is not possible Unit Status ...

Page 4: ...KX HGT100 Configuration 3 STATIC IP is set by default Default IP 192 168 0 241 Default Subnet Mask 255 255 255 0 Network Status ...

Page 5: ...guration 4 LAN Connection STATIC IP or DHCP Mode can be selected Static IP is Default X NB If you select DHCP here you will need to re connect your browser using the allocated IP address before continuing to configure ...

Page 6: ...KX HGT100 Configuration 5 Enter IP Address etc of HGT100 here DNS Server Address can be added here not required for TDE NCP After clicking Save please power off on the HGT 100 ...

Page 7: ... HGT 100 otherwise Internet access from the PC will not be possible The allocated IP address can be checked by pressing the i key on the HGT 100 To re connect with a browser after enabling DHCP enter the allocated IP address i e Allocated IP address 10 66 55 44 URL http 10 66 55 44 After clicking Save power off on the HGT 100 ...

Page 8: ...X HGT100 Configuration 7 Username and Password Modifies the HTTP Login User name and Password from default If Idle Timeout expires unit will need to be powered off on to re open HTTP port Special Setting ...

Page 9: ...ettings Refer to next slide for language parameters SIP Extension details and password Telephone Number and SIP ID can match SIP Proxy Registrar and Domain information For NCP Extension enter the IP address of the NCP for all settings ...

Page 10: ...KX HGT100 Configuration 9 Basic Settings Example Stand Alone SIP Telephone configuration with Gamma SIP Account SIP Number Account and password SIP Proxy Registrar and Domain IP or DNS ...

Page 11: ... Permits or Denies CLIP sending on a per call basis depending on the My Caller ID setting of the HGT100 RTP Port Range Voice Traffic Codec Priority PCMA U G711A U G726 32 N A for TDA NCP G729A DTMF Type Inband Outband RFC2833 SIP UDP Control port Diffserv ToS field settings ...

Page 12: ...uration 14 Configuration File Basic Configurations can be backed up and or loaded via this screen This allows a dealer to create a profile template and then modify only a small number of parameters Number Password etc ...

Page 13: ...KX HGT100 Configuration 15 Upgrade Firmware Firmware updates can be managed easily from this page Power off on the unit to complete the upgrade ...

Page 14: ...KX HGT100 Configuration 16 Unit Maintenance Lan PC Port Speed Duplex Settings Auto Negotiate 100Mbps Full Duplex 100Mbps Half Duplex 10Mbps Full Duplex 10Mbps Half Duplex Auto Sense is supported ...

Page 15: ... PROGRAM KEY LCD DISPLAY NAVI KEY INFORMATION KEY MUTE KEY KX HGT100 User Setting 1 OK KEY AUTO HOLD Message Transfer SP Phone Key SP Phone Hold and Message Keys have LED REDIAL KEY ...

Page 16: ...Save Speed Dial OK YES KX HGT100 User Setting 2 Saved in No 1 Select OK PROGRAM Enter No 1 No 1 OK SET 0123456789 Speed dial 0 9 1 How to access OFF HOOK Keys used 1 AUTO ...

Page 17: ...Set Date Time OK YES KX HGT100 User Setting 3 Enter Year 2008 OK Enter Month Day 05 07 OK Enter Time 17 30 OK AM PM 24H 17 30PM OK My Caller ID Show OK YES OK Select Show Hide OK CLIR Show Hide 2 3 ...

Page 18: ...tting 4 LCD contrast OK YES 4 OK YES Select 4 STEPS Ringer Tone Ring 1 OK YES 5 Ringer Tone Ring 2 OK YES Select 3 STYLES Ringer Volume Ring 1 OK YES 6 Ringer Volume OK OFF Select 4 Position OFF OFF SP Phone LED Flashes ...

Page 19: ...KX HGT100 User Setting 5 7 Set Hold Music 01 OK YES Select OK 11 Settings Inc OFF 8 KeyTone Volume OK YES Keytone Volume OFF OK Select 3 Settings Inc OFF Time AM PM 24H AM OK YES 9 OK Select AM PM 24H ...

Page 20: ...10 Change Language English OK OK Select Refer to Slide 14 for supported languages Set Network STATIC OK YES 11 OK Select STATIC IP Or DHCP IP Address OK 192 168 010 003 Subnet Mask OK 255 255 255 0 Default GW OK 192 168 000 001 ...

Page 21: ...KX HGT100 User Setting 7 Select IP Address 192 168 010 003 Subnet Mask 255 255 255 0 Default Gateway 192 168 000 001 INFORMATION Own number 01234 1 Status Normal 2 Network STATIC 3 6 5 4 ...

Page 22: ...figured Web Setting will be displayed in the LCD HTTP Port open To re open the HTTP Port after initial setting or Idle time out default 30min OK Mute and power on the unit Firmware Roll back To rollback the firmware to the previously installed version Program Mute and power on the unit Panasonic Telephone Systems See More Panasonic Manuals www voicesonic com Phone 877 289 2829 ...