95
KX-FT982LS-B / KX-FT984LS-B / KX-FT988LS-B
OK means "can set".
NG means "can not set".
Note:
•
*1
Power is OFF/ON after changing this set value.
•
*2
Vox test is available for KX-FT988 only.
• Refer to
Service Function Table
(P.60) for descriptions of the individual codes.
Example:
If you want to set value in the "004 Sending report", press the dial key number 1, 2 or 3 corresponding to the Set Value you want
to select. (1:ERROR/2:ON/3:OFF)
557
LED test
---------
---------
NG
558
LCD test
---------
---------
NG
559
Document jam detection select
1: ON / 2: OFF
ON
OK
560
Cutter selection (KX-FT984/KX-FT988 only)
1: ON / 2: OFF
ON
OK
561
Key test
---------
---------
NG
562
Cutter test (KX-FT984/KX-FT988 only)
---------
---------
NG
567
T0 timer
001 ~ 255 sec
046 sec
OK
570
Break % select
1: 61% / 2: 67%
67%
OK
571
ITS auto redial time set
00 ~ 99
00
OK
572
ITS auto redial line disconnection time set
001 ~ 999 sec
065 sec
OK
573
Remote turn-on ring number set
00 ~ 99
10
OK
580
TAM continuous tone detection (KX-FT988 only)
1: ON / 2: OFF
ON
OK
590
FAX auto redial time set
00 ~ 99
02
OK
591
FAX auto redial line disconnection time set
001 ~ 999 sec
065 sec
OK
592
CNG transmit select
1: OFF / 2: ALL / 3: AUTO
ALL
OK
593
Time between CED and 300 bps
1: 75 msec / 2: 500 msec / 3: 1 sec
75 msec
OK
594
Overseas DIS detection select
1: 1st / 2: 2nd
1st
OK
595
Receive error limit value set
1: 5% / 2: 10% / 3: 15% / 4: 20%
10%
OK
596
Transmit level set
00 ~ 15
×
-1 dBm
11
×
-1 dBm
OK
598
*1
Receiving Sensitivity
20 ~ 48
×
-1 dBm
42
×
-1 dBm
OK
710
Memory clear except History data
---------
---------
NG
717
Transmit speed select
1: 9600 / 2: 7200/ 3: 4800 / 4: 2400 bps
9600 bps
OK
718
Receive speed select
1: 9600 / 2: 7200/ 3: 4800 / 4: 2400 bps
9600 bps
OK
722
Redial tone detect
1: ON / 2: OFF
OFF
OK
763
CNG detect time for friendly reception
1: 10 sec / 2: 20 sec / 3: 30 sec
30 sec
OK
773
DIS-DCS interval
1: 500 msec / 2: 200 msec
200 ms
OK
774
T4 timer
00~99
×
100 msec
00
×
100 ms
OK
784
Voice Prompt Test (KX-FT988 only)
---------
---------
NG
815
Sensor test & Vox test
*2
---------
---------
NG
841
Digital SP-Phone RX & TX check (KX-FT988 only)
---------
---------
NG
845
Setting scanning density
00 ~ 32
08
OK
852
Print test pattern
---------
---------
NG
853
Top margin
1 ~ 9 mm
5 mm
OK
874
DTMF ON time
06 ~ 20
×
10msec
10
×
10 msec
OK
875
DTMF OFF time
06 ~ 20
×
10msec
10
×
10 msec
OK
880
History list
---------
---------
NG
881
Journal 2
---------
---------
NG
882
Journal 3
---------
---------
NG
961
The time transmitting the false ring back tone
01~10 sec
07 sec
OK
962
The operator calling time
05~30 sec
10 sec
OK
991
Setup list
1: Start
---------
OK
994
Journal list
1: Start
---------
OK
995
Journal 2 list
1: Start
---------
OK
996
Journal 3 list
1: Start
---------
OK
998
History list
1: Start
---------
OK
999
Service list
1: Start
---------
OK
Code
Function
Set Value
Default
Remote Set-
ting
Summary of Contents for KX-FT982LS-B
Page 2: ...2 KX FT982LS B KX FT984LS B KX FT988LS B ...
Page 12: ...12 KX FT982LS B KX FT984LS B KX FT988LS B 6 Technical Descriptions 6 1 Connection Diagram ...
Page 14: ...14 KX FT982LS B KX FT984LS B KX FT988LS B 6 2 1 General Block Diagram ...
Page 22: ...22 KX FT982LS B KX FT984LS B KX FT988LS B 6 4 2 Block Diagram ...
Page 24: ...24 KX FT982LS B KX FT984LS B KX FT988LS B ...
Page 72: ...72 KX FT982LS B KX FT984LS B KX FT988LS B Countermeasure ...
Page 73: ...73 KX FT982LS B KX FT984LS B KX FT988LS B REFERENCE Test Mode P 55 ...
Page 74: ...74 KX FT982LS B KX FT984LS B KX FT988LS B REFERENCE Test Mode P 55 ...
Page 75: ...75 KX FT982LS B KX FT984LS B KX FT988LS B REFERENCE Test Mode P 55 ...
Page 76: ...76 KX FT982LS B KX FT984LS B KX FT988LS B REFERENCE Test Mode P 55 ...
Page 77: ...77 KX FT982LS B KX FT984LS B KX FT988LS B ...
Page 78: ...78 KX FT982LS B KX FT984LS B KX FT988LS B ...
Page 79: ...79 KX FT982LS B KX FT984LS B KX FT988LS B REFERENCE Test Mode P 55 ...
Page 83: ...83 KX FT982LS B KX FT984LS B KX FT988LS B ...
Page 109: ...109 KX FT982LS B KX FT984LS B KX FT988LS B NG Wave pattern Note Refer to NG Example P 114 ...
Page 111: ...111 KX FT982LS B KX FT984LS B KX FT988LS B I O and Pin No Diagram ...
Page 114: ...114 KX FT982LS B KX FT984LS B KX FT988LS B 12 5 6 2 NG Example ...
Page 116: ...116 KX FT982LS B KX FT984LS B KX FT988LS B ...
Page 121: ...121 KX FT982LS B KX FT984LS B KX FT988LS B 12 5 9 2 Troubleshooting Flow Chart ...
Page 128: ...128 KX FT982LS B KX FT984LS B KX FT988LS B 13 Service Fixture Tools ...
Page 134: ...134 KX FT982LS B KX FT984LS B KX FT988LS B 14 2 2 How to Remove the P C Boards and Power Cord ...
Page 138: ...138 KX FT982LS B KX FT984LS B KX FT988LS B 14 3 3 How to Remove the Separation Rubber Flap ...
Page 139: ...139 KX FT982LS B KX FT984LS B KX FT988LS B 14 4 Installation Position of the Lead Wires ...
Page 140: ...140 KX FT982LS B KX FT984LS B KX FT988LS B ...
Page 148: ...148 KX FT982LS B KX FT984LS B KX FT988LS B 15 2 3 4 Copying REFERENCE Sensor Section P 124 ...
Page 153: ...153 KX FT982LS B KX FT984LS B KX FT988LS B 16 1 4 Power Supply Board ...
Page 155: ...155 KX FT982LS B KX FT984LS B KX FT988LS B 16 3 Test Chart 16 3 1 ITU T No 1 Test Chart ...
Page 156: ...156 KX FT982LS B KX FT984LS B KX FT988LS B 16 3 2 ITU T No 2 Test Chart ...
Page 157: ...157 KX FT982LS B KX FT984LS B KX FT988LS B MEMO ...
Page 170: ...170 KX FT982LS B KX FT984LS B KX FT988LS B MEMO ...
Page 180: ...180 KX FT982LS B KX FT984LS B KX FT988LS B 20 1 1 Operation Panel Section KX FT982 KX FT984 ...
Page 181: ...181 KX FT982LS B KX FT984LS B KX FT988LS B 20 1 2 Operation Panel Section KX FT988 ...
Page 182: ...182 KX FT982LS B KX FT984LS B KX FT988LS B 20 1 3 Upper Cabinet Section ...
Page 183: ...183 KX FT982LS B KX FT984LS B KX FT988LS B 20 1 4 Lower Cabinet Section ...
Page 184: ...184 KX FT982LS B KX FT984LS B KX FT988LS B 20 1 5 Gear Block Section ...
Page 185: ...185 KX FT982LS B KX FT984LS B KX FT988LS B 20 1 6 Screws ...
Page 186: ...186 KX FT982LS B KX FT984LS B KX FT988LS B 20 1 7 Accessories and Packing Materials ...