KX-FT21LA
- 106 -
HOW TO REPLACE THE FLAT PACKAGE IC
If you do not have the special tools (for example: SPOT HEATER) to remove the SPOT HEATER'S Flat IC, if you have solder
(large amount), a soldering iron, and a cutter knife, you can easily remove the ICs even if there are more than 100 pins.
1. PREPARATION
2. FLAT PACKAGE IC REMOVAL PROCEDURE
SOLDER
Sparkle Solder 115A-1, 115B-1
OR
Almit Solder KR-19, KR-19RMA
Soldering iron
Recommended power consumption is between 30 W to 40 W.
Temperature of Copper Rod 662 • } 50
ß
F (350 • }10• • )
(An expert may handle a 60~80 W iron, but a beginner might
damage the foil by overheating.)
Flux
HI115 Specific gravity 0.863
(Original flux should be replaced daily.)
2) Using a cutter, cut the lead at the source.
(Cut the contents with a cutter lightly, 5 or 6 times.)
Cutter
Solder
1) When all of the IC lead cannot been seen at the
standard degree, fill with large quantities of solder.
Note:
If you do not fill with solder and directly cut the IC lead
with the cutter, stress may build up directly in the P.C.
board's pattern. If you do not fill with large quantities of
solder as in step 1, the P.C. board pattern may be
removed.
Solder
3) Remove when the solder melts.
(Remove the lead at the same time.)
Solder
Summary of Contents for KX-FT21BX
Page 14: ... 14 Model KX FT21BX KX FT21BX W KX FT21BX KX FT21BX W MEMO ...
Page 36: ...KX FT21LA 10 CCITT NO 1 TEST CHART Actual size ...
Page 97: ...TROUBLESHOOTING GUIDE 71 KX FT21LA MEMO ...
Page 117: ...TROUBLESHOOTING GUIDE 91 KX FT21LA 6 1 PRINTOUT EXAMPLE ...
Page 118: ...KX FT21LA 92 ADJUSTMENTS Page 1 Adjusting the Feeder Pressure 93 ...
Page 178: ...KX FT21LA 152 MEMO ...
Page 192: ...KX FT21LA 166 FIXTURES AND TOOLS EC8 EC5 EC7 EC3 EC1 EC2 EC2 EC4 EC6 ...
Page 198: ...KX FT21LA 172 A6 P2 A7 P3 A4 A1 P4 P5 P1 A5 A3 A2 ACCESSORIES AND PACKING MATERIALS ...
Page 206: ...KX FT21LA 180 D Q KXFT21LA Printed in Japan ...