Simple Power On Sequence (DX Series)
Power SW on / Remote on
< Display start >
( Plug in )
41
Power Off
Standby
Power On
16V / 32(*)V output / PFC circuit start working
TV_SUB_ON signal
STB5V output
Stop 16V / 32(*)V
PNL12V output
PANEL_VCC_ON2 signal
Power LED Green
Stop 16V / 32(*)V
Power LED off
TV_SUB_OFF
TV_SUB_OFF
AC Plug in
STB5V (form P to A)
16V (from P to A)
PNL12V (from A to Panel(T-CON) )
SUB_ON (from A to P)
Power LED
Panel_Vcc_ON (from A to Panel(TCON))
VLED (from P to Panel(Backlight) )
BL_ON (from A to Panel(Backlight))
(Standby)
Power on
(Standby)
Power on
Power on
North America :
(Power LED Green RED)
(Power LED Red OFF)
(Power Off no exist)
Also 16V is necessary before Power LED on at first time.
Standby / Power on
5V
16V
12V
Ex.24V
VLED
16V / 32(*)V up to VLED
BL_ON_ON signal
< DX series >
Power LED Red
(*) The DC level is different by the LCD panel.