System settings
14.3 Activation of system settings in system mode
Normal
operation
If HMWIN runtime is not running:
Touch the “System Setting” button on the touch terminal to open the system set-
tings in user mode. Select “Restart” > “Config OS” to reboot in system mode.
If HMWIN runtime is running:
Touch and hold any unused area of the touchscreen for a few seconds to access
the context menu. The default holding time is 2 seconds. Select “System Setting”
from the context menu. Select “Restart” > “Config OS” to reboot in system mode.
Recovery
operation
If the touch terminal is not responsive, tap on the surface of the touchscreen during
the power-up phase. The tapping frequency must be high. Start tapping the touch-
screen as soon as power has been supplied to the product.
The message “TAP-TAP DETECTED” appears when the operating sequence has
been recognized. Release the touchscreen to boot in user mode without running
HMWIN runtime or touch and hold the touchscreen for a few seconds. Then select
“Restart” > “Config OS” to boot in system mode.
14.4 Options available in system settings
The following important basic setting options of the touch terminal are available:
Language
Configure the language used for the system setting menu only.
System
Shows information about platform, status and timers (e.g. system
on time, backlight on time).
Logs
Enable continuous log for BSP and allow to export it.
Date & Time
Change the date and time of the product, including time zone and
NTP server.
Network
Configure the IP address of the Ethernet interface and the other
network settings, e.g. DNS, gateway, DHCP, hostname, routing
and bridging.
Services
Enable/disable services, e.g. OpenSSH server, bridge, cloud
services, router, SNMP and logging.
Management
Update BSP components (Main OS, Config OS, Boot loader,
XLoader), check partition consistency, update the splash screen,
show the usage and size of partitions.
The update of “Main OS” is only available in system mode. The
update of “Config OS” is only available in user mode.
Display
Adjust the display brightness, configure automatic backlight turn-
off and select panel orientation (90°, 180°, 270° and 360°).
Restart
Restart the product.
Select “Main OS” to restart the product in user mode. Select
“Config OS” to restart the product in system mode and open the
system settings.
Authentication
Configure the administrator (“admin”) and standard user (“user”)
password. An administrator has full access to the “System
Settings” (e.g. BSP updates and other system components). A
standard user has some limitations.
NOTE
There are more options available in the system settings that are not described and not documented in
this manual. For details, refer to the HMWIN User Manual.