background image

INSTRUCTION MANUAL

Ultra High-Speed, High-Accuracy Laser Displacement Sensor

Sensor Head

HL-C211F(E), HL-C211F(E)-MK

MJE-HLC211F(06) No.0059-73V

Thank you very much for purchasing Panasonic products. Read this Instruction Man-

ual carefully and thoroughly for the correct and optimum use of this product. Kindly 

keep this manual in a convenient place for quick reference.

WARNING

 

 This product is intended to detect the objects and does not have the control func-

tion to ensure safety such as accident prevention.

Do not use the product as a sensing device to protect human body.

 

 

Be careful not to directly watch or touch the direct laser beam or reflected laser beam.

 

The product was developed and manufactured for industrial use.

BEFORE USE

 

Before using the product, check the sensor head model and contents of packing.

 

 Sensor head model

Check the model name of product at the top of sensor head.

 

 Packing

Check that all of the following components are included in the 

package.

•  1 sensor head unit

•  1 Instruction manual

•  Laser warning labels

[JIS/IEC/KS: 1 set, GB: 1 set (E type only), FDA: 1 set]

 

●  This product satisfies the adaption of CE product by using in combination with 

controller and programmable display, which are subjected to CE. Please confirm 

that there is CE mark on connecting controller’s label.

1

DESCRIPTION

 

 

HL-C211F

(

E

), 

HL-C211F

(

E

)-

MK

 displacement sensor head achieves ultra high-

speed and high-accurate measurement using linear image sensor as light receiv-

ing element to be used on equipment that require high-speed operation with high-

accuracy.

 

 

The product is used at diffuse or specular reflection sensor head by installing and setting.

2

CAUTIONS ON HANDLING LASER LIGHT

 

In order to prevent the accidents by laser product and protect the users, IEC, JIS,  

GB, KS and FDA establish the following standards respectively.

IEC  :  IEC 60825-1

-2014

JIS  :  JIS C 6802

-2014

GB  :  GB 7247.1

-2012

KS  :  KS C IEC 60825-1

-2013

FDA :  PART 1040(PERFORMANCE STANDARDS FOR LIGHTEMITTING PRODUCTS)

These standards classifies laser products according to the level of hazard and pro

-

vide the safety measures for respective classes (Refer to the “FDA Standard” table).

 

 FDA  standard

Requirements

Class 

*1

I

IIa

II

IIIa

IIIb

IV

Performance (all laser products)

Protective housing [1040.10 (f) (1)]

Safety interlock [1040.10 (f) (2)]

Location of controls [1040.10 (f) (7)]

Viewing optics [1040.10 (f) (8)]

Scanning safeguard [1040.10 (f) (9)]

*2

*3,4

N/A

R

R

*2

*3,4

R

R

R

*2

*3,4

R

R

R

*2

*3,4

R

R

R

*2

*3,4

R

R

R

*2

*3,4

R

R

R

Performance (laser system)

Remote control connector [1040.10 (f) (3)]

Key control [1040.10 (f) (4)]

Emission indicator [1040.10 (f) (5)]

Beam attenuator [1040.10 (f) (6)]

Reset [1040.10 (f) (10)]

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

R

R

N/A

N/A

N/A

R

R

N/A

R

R

*10

R

N/A

R

R

*10

R

*13

Performance (specific-purpose products)

Medical [1040.11 (a)]

Measurement, leveling, alignment [1040.11 (b)]

Demonstration [1040.11 (c)]

S

S

S

S

S

S

S

S

S

*8

S

S

*8

NP

*11

*8

NP

*11

Labeling (all laser products)

Certification/identification [1010.2,3]

Protective housing [1040.10 (g) (6),(7)]

Aperture [1040.10 (g) (4)]

Class warning [1040.10 (g) (1),(2),(3)]

R

*5

N/A

N/A

R

*5

N/A

*6

R

*5

N/A

*7

R

*5

N/A

*9

R

*5

N/A

*12

R

*5

N/A

*12

Information (all laser products)

User information [1040.10 (h) (1)]

Product literature [1040.10 (h) (2) (i)]

Service information [1040.10 (h) (2) (ii)]

R

N/A

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R  : Required

N/A :  Not  applicable

S  :  Same as for other products of that Class. Also see footnotes.

NP :  Not permitted

D  :  Depends on level of inner radiation

*1  : Class is based on the maximum level of laser exposure during operation.

*2  : Required wherever and whenever human access to laser radiation above Class I limits is not 

needed for product to perform its functions.

*3  : Required for protective housings opened during operation or maintenance, if human access 

thus gained is not always necessary when housing is opened.

*4  : The requirements for interlock differ depending on the class of inner radiation.

*5  : The contents of label differ depending on the level and wavelength of laser radiation inside the 

protective housing.

*6  : Warning statement label

*7  : CAUTION logotype

*8  : The method to measure the level of laser radiation to human body is required.

*9  : CAUTION if 2.5mWcm

-2

 or less, DANGER is greater than 2.5mWcm

-2

.

*10 : Time difference is needed between instruction and emission.

*12 :  DANGER logotype

*13 : Required after August 20, 1986.

 

 Warning / Aperture label

 

 Certification / Identification label

 

 WARNING  label

In Chinese

In Japanese / English / Korean

(E type only)

<Label position>

 

 Install the product so the laser beam comes higher or lower than eye level in or-

der not to watch the beam directly during operation.

Laser safety distance (Nominal Ocular Hazard Distance: NOHD) is approx. 0.5m. The 

laser beam must be terminated at the end of its path by a diffuse reflector or an absorber.

 

 Please contact our company if the system breaks down. It is not equipped with a func-

tion that stops laser radiation automatically during disassembling the sensor head. 

The users therefore may be exposed to laser beam in disassembling the sensor head.

 

 

Do not use the system in the manner other than specified in this Instruction Manual.

3

EXPORT REGULATIONS BY JAPANESE GOVERNMENT

 

 

HL-C211F 

and 

HL-C211F-MK

 are subject to export control regulation by the For-

eign Exchange and Foreign Trade Law. Export admission by Japanese govern-

ment is required before the product is to be exported or brought out of the country.

These products are also subject to Article 1.B.3.b.1 of Nuclear Suppliers Group in 

international export control regime and 2.B.6.b.1 of Wassenaar Arrangement.

 

 Please follow the export control regulations required.

HL-C211FE 

and 

HL-C211FE-MK

 (E type) are not subject to export control regula-

tions under the condition that they are used combined with the non-pertinent con-

troller to export control specified by Foreign Exchange and Foreign Trade Law.

When they are combined with the pertinent controller to export control, they are 

subject to the Law. In this case export admission by Japanese government is re-

quired before the product is to be exported or brought out of the country.

4

SPECIFICATIONS

Model No.

HL-C211F

(

E

)

HL-C211F

(

E

)

-MK

Diffuse Reflection

Specular Reflection

Diffuse Reflection

Specular Reflection

Meas. method (Note 2)

Diffuse reflection / Specular reflection

Measurement center distance

110mm

106.7mm

110mm

106.7mm

Measurement range (Note 3)

±15mm

±14.5mm

±15mm

±14.5mm

Beam source

Red semiconductor laser Class II (FDA), Class 2 (JIS/IEC/GB/KS)

Max output: 1mW, Emission Peak wavelength: 658nm

Beam diameter (Note 4)

Approx. 

ø

80μm

Approx. 80 × 1,700μm

Beam receiving element

Linear image sensor

Resolution

0.4μm / average times: 256, 0.1μm /average times: 4,096

[E type (Note 5) 0.25μm / average times 256]

Linearity

±0.03%F.S.

Temperature characteristics

0.01%F.S./°C

Indicator

Laser emission

Green LED: Lights up during laser emission.

Meas. range

Yellow LED: Near measurement center:ON, within measurement range:Blink, beyond the range:OFF

Protective structure

IP67 (except connector)

Pollution degree

2

Insulation resistance

20M ohms or more by 500V DC megger (between all the terminals and enclosure.)

Dielectric withstand

Commercial Frequency

AC 500V for 1min. (between all the terminals and enclosure.)

Impulse

±

1,000V 1.2/50μs (between all the terminals and enclosure.)

Vibration resistance

Endurance: 10 to 55Hz (cycle: 1minute), Resistant amplitude of vibration: 1.5mm, in 

X, Y, and Z directions for 2 hours

Shock resistance

196m/ s

2

 in X, Y, and Z directions for 3 times

Ambient illuminance (Note 6)

3,000ℓx or less (illuinance at beam receiving surface using incandescent lamp)

Ambient temperature

0 to +45°C (No dew condensation or icing allowed), At storage: -20 to +70°C

Ambient humidity

35 to 85%RH At storage:35 to 85%RH

Ambient Height

2,000m or less

Material

Main unit case / cover faluminum: Die-cast, Front cover: Glass

Cable length

0.5m

Cable extension

Extendible to 30m long maximum using the optional extension cable.

Weight

Approx. 300g including cable weight

Applicable regulations

Conformed to EMC Directive

Notes: 1) Measuring conditions are as follows unless otherwise specified; connection with controller, power voltage: 

24V DC, ambient temperature: 20°C, sampling cycle: 40μs, average times:256, at measurement center dis

-

tance, object substance: white ceramic,, and digital measurement value.

 2) 

Use the external ND filter (optional) in case the amount of reflected beam is too large on Specular Reflection installation.

 3) 

The measurement range is limites b0.5 and +15.0mm (in case the sampling cycle is 20μs at diffuse reflection), between 

+0.5 and +14.5mm (in case the sampling cycle is 20μs at specular reflection), b12.5 and +15.0mm (in case the sampling 

cycle is 10μs at diffuse reflection), or b12.5 and +14.5mm (in case the sampling cycle is 10μs at specular reflection).

 

4) The figure shows the value at measurement center distance. It is determined by 1/e

2

 (approximately 13.5%) 

of center beam intensity. Due to leak light outside the specified area, the reflectance around the detecting 

point may be higher than at the point and this may affect the measurement value.

 

5) The minimum resolution of 0.25μm can be achieved if the sensor head is connected to the controller that is 

not subject to “Foreign Exchange and Foreign Trade Law”.

 

6) The variation in ambient illuminance is ±0.03%F.S. or less.

Reviews: