background image

5

CAUTIONS

Connection

 

 Turn off the power of controller before connecting or disconnecting the connectors.

 

 When connecting or disconnecting the connectors, be sure to hold the connector 

area not to apply extra force to the cable.

 

 Be careful not to touch terminals or to let foreign matter get in the connector after 

disconnecting connectors.

 

 Be careful not to apply force to around the connector of standard cable and ex-

tension cable. Do not bend the cables near connectors. Failure to do so causes 

causes disconnection of the cable.

 

 When moving the sensor head during operation, install it so the cable not bend 

bend during movement. Use replaceable extensions cable in case the cable 

needs bend.

Wiring

 

 Do not run the sensor cable along (bundled in parallel) with other wirings. Keep it 

at least 100mm away from other wires. Run the cable so it is separate from high 

voltage and power circuit lines. If it is necessary to run the cable in parallel with 

them, shield it by running through a grounded electrical conduit.

 

Install the product as far away as possible from noise source such as high-voltage 

lines, high-voltage device, power lines, power device, machines which generate a 

large starting and stopping surge, welding machines and inverter motor.

 

 Do not pull the cable using a force more than 

29.4N when routing the cable with the sen-

sor head and controller fixed. At least 20 mm 

is required from the cable connection to the 

bend. The bending radius must be 30 mm or 

more.

 

 Use only 1 extension cable for connection 

between one sensor head and a controller.

20mm or more

R30mm or more

Warming up time

 

 Allow at least 30 minutes of warming up after turning on the power to ensure the 

performance of the product.

Environment

 

 The life of the semiconductor laser depends on the ambient temperature during 

use. When using the product near a heat source, take measures to lower the am-

bient temperature of the sensor head as possible. Mount the sensor on a device 

having good heat radiation because the sensor itself emits heat.

 

● Water, oil, or fingerprints on the emitter surface and receiver surface of sensor 

head reflects light. Dust and dirt on them block light. Keep them clean at all times. 

When cleaning these parts, wipe them off using a soft lint-free cloth or lens clean-

ing paper.

 

Install the sensor head so ambient light such as sunlight or light with the same 

wavelength as laser beam should not enter the light receiver. If high accuracy is 

required, install a light shielding plate or the like on the sensor head.

 

The controller and connectors are not structurally dustproof, waterproof, or corro-

sion-resistant. Do not use the product underwater or in the rain.

 

● Do not use the product in dusty places or that exposed to flammable or corrosive 

gases, droplet, direct sunlight, severe vibration or impact.

6

MEASUREMENT RANGE / INDICATOR

 

Installation Mode: Diffuse

Meas. range indicator

OFF

Blink

OFF

Blink

ON

Measurement range

Measurement center 

distance

 

Installation Mode: Specular

Meas. range indicator

OFF

Blink

OFF

Blink

ON

Measurement range

Measurement center 

distance

 

● The measurement range indicator at sampling cycle of 20μs or 10μs lights up at 

the center of limited measurement range.

7

MUTUAL INTERFERENCE AREA (Unit: mm)

 

 When installing 2 or more sensor heads 

side by side, mutual interference occurs if 

the laser spots from other sensor heads fall 

within the shaded areas in the right figure. 

Install sensor heads so the laser spots from 

other sensor heads fall outside the shaded 

areas.

8

BEAM DIAMETER (Unit: mm)

0.22

0.03

0.22

0.85

1.2

1.55

0.18

0.18

0.03

0.03

0.18

0.18

HL-C203F

(

E

)

Minimal spot type

HL-C203F

(

E

)

-MK

Line spot type

Measurement range

Measurement center distance

9

DIMENSIONS (Unit: mm)

 

Installation Mode: Diffuse

Beam Attenuator

(Measurement center distance)

Light

emission axis

Light

reception axis

2-M5 mounting hole

Depth:10

(opposite surface)

Measurement

range indicator

(yellow)

Laser emission 

indicator

(green)

 

Installation Mode: Specular

Beam Attenuator

Specular reflection line
The reference surface for specular reflection installation

(Measurement center distance)

Light emission axis

Light reception axis

10

OPTION

 

● ND filter (product code: 

HL-C2F01

) is optionally available to adjust the excessive 

received light intensity to an optimum level. This is useful when mounting the sen-

sor head for specular reflection.

http://panasonic.net/id/pidsx/global

Overseas Sales Division (Head Office) 

2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan 

Phone: +81-568-33-7861  FAX: +81-568-33-8591

About our sale network, please visit our website.

PRINTED IN JAPAN

© Panasonic Industrial Devices SUNX Co., Ltd. 2017 

Reviews: