Anomaly
Possible Cause
Corrective Action
section
The Oven lights
are always OFF.
No power supply.
Check door micro
switch.
Replace door micro
switch.
Power board relay
not switching.
Replace Power board. 7.16.
The Oven lights
are always OFF.
Power supply is
ok.
Lamps are burned
out.
Replace lamps.
The Oven lights
are always ON.
Check the door
micro switch.
Replace door micro
switch or connection
between the door
switch and the power
board.
Power board relay
has a shorted cir-
cuit.
Replace Power board. 7.10.
Anomaly
Possible Cause
Corrective Action
section
Every cooking
mode accepts
only the preset
temperature and
clean will not start.
The control can-
not read the tem-
perature selector.
Check the connec-
tions between the
selectors and the dis-
play board.
--
Check and eventually
replace the selector
itself.
Check and eventually
replace the power
board.
The control
doesn't accept
any cooking mode
or clean selection.
The control can-
not read the cook-
ing mode selector.
Check the connec-
tions between the
selectors and the dis-
play board.
--
Check and eventually
replace the selector
itself.
Check and eventually
replace the power
board.
Anomaly
Possible Cause
Corrective Action
section
The display is
always dark, the
latch at power up
works correctly.
The power supply
to the display
board is missing.
Verify if the voltage (-
5GND) is correct on
the display board.
--
Check the connec-
tions between the
power and the display
board.
--
Verify if the voltage (-
5GND) is correct on
the main power board.
--
The display is
always dark, the
latch at power up
doesn’t work
The power supply
is not working.
Verify if the voltage (-
5GND) is correct on
the main power board.
--
Check and eventually
replace the main
power board.
During the manual
test it’s not possi-
ble to check the
software version
of one board: The
displays shows [d]
or [p] without any
number.
The board has
never been pro-
grammed.
If the display shows
2p check the connec-
tions between the
boards, then try to
replace the bad power
connection.
--
The display can-
not read the
power board soft-
ware due to a
connection prob-
lem.
if the display shows
[d] replace the display
board.
Anomaly
Possible Cause
Corrective Action
section
The door does
not close or there
is not sealing
between door
and gasket
Hinges system is
broken or dam-
aged
Replace the units
The hinges sup-
port in the box is
broken or dam-
aged
Replace the units
Anomaly
Possible Cause
Corrective Action
section
Bad performance Heating ele-
ments not work-
ing
Check the connection
of the heating ele-
ments
--
If there in not power
on the heating ele-
ments check relays on
the power boards.
If the power board
relay not switching
replace the units.
Check the power on
the heating elements
and replace the ele-
ments if needed
Convection fan
not working prop-
erly
See the convection
fan problem
There is not seal-
ing between door
and gasket
The hinges system or
the hinges support in
the box are damaged.
Replace the units
Anomaly
Possible Cause
Corrective Action
section
Meat seems to
be not present or
doesn’t work
Bad connec-
tions or short cir-
cuit
Check the harness
near the probe con-
nection
Meat probe inter-
nal wires are bro-
ken
Replace the meat
probe
--
Anomaly
Possible Cause
Corrective Action
section
Summary of Contents for HL-BD82S
Page 30: ...HL BD82S 30 8 Wiring Connection Diagram ...
Page 31: ...HL BD82S 31 9 Exploded View and Replacement Parts List 9 1 Exploded View_A ...
Page 32: ...HL BD82S 32 9 2 Exploded View_B ...
Page 33: ...HL BD82S 33 9 3 Exploded View_C ...
Page 34: ...HL BD82S 34 9 4 Exploded View_D ...