4
Note) A module is installed using 4 points, symmetrical mounting within setting range (shaded).
Setting range parameters are shown in
“
Mount Locations and Load Resistance
”
table.
Figure 1: Module dimensions
Dimensions in mm
Side
* The positions of the holes are all symmetrical against the center
of the module.
Front side
Section A
-
A
’
Section B
-
B
’
Back side
Mounting location range
L1
0
230
-
230
L2
450
380
-
345
S1
-
-
0
-
S2
-
-
250
-
Load resistance (Positive load)
2400 Pa
5400 Pa
2400 Pa
5400 Pa
Load resistance (Negative load)
2400 Pa
4400 Pa*
2400 Pa
5400 Pa
Module locations and load resistance
* Depending on internal standard