background image

1

INSTRUCTION MANUAL

Micro Laser Distance Sensor (CMOS)

HG-C Series

ME-HGC1000V3EN 05/2017

Thank you very much for purchasing Panasonic products. Please read this 

Instruction Manual carefully and thoroughly for the correct and optimum 

use of this product. Kindly keep this manual in a convenient place for quick 

reference.

WARNING

 

This product is intended to detect objects. Do not use it to carry out 

safety control functions to prevent accidents.

 

Never use this product as a sensing device for personnel protection.

 

Do not look into the beam directly during operation.

1

CE marking

This product complies with the following standards and 

regulations.

 

For the EU: EMC Directive 2014/30/EU 

Contact for CE: 

Panasonic Marketing Europe GmbH 

Panasonic Testing Center 

Winsbergring 15, 22525 Hamburg, Germany 

2

Confirmation of packed content

 

Sensor

1 pc. 

 

Laser warning label (JIS Standards, GB Standard) 1 set each

 

● FDA certification label

1 pc.

 

 Instruction Manual (Japanese, English)

1 pc. per language

3

Safe use of laser product

In order to prevent accidents caused by laser products and to protect the 

users, IEC, JIS and FDA established the following standards:   

IEC: 

IEC 60825-1-2007 (EN 60825-1-2007) 

JIS: 

JIS C 6802-2011 

FDA: 

PART 1040 (Performance standards for light-emitting products)

These standards classify laser products according to their level of hazard 

and provide safety measures for the respective classes.

Warning label and position

LASER  RADIATION

LASER  APERTURE

CLASS2 LASER PRODUCT

(IEC60825-1 2007)

(MAXIMUM OUTPUT) 1mW

(PULSE DURATION) 5ms max. 

(WAVELENGTH) 655nm

DO NOT STARE

INTO BEAM

An English warning label is attached to this product.

4

Part description

5

6

7

8

9

1

2

3

4

No.

Item

1

Zero set indicator (Yellow)

2

Teaching indicator (Yellow)

3

Output operation indicator (Orange)

4

Laser emission indicator (Green)

5

TEACH key

6

UP key

7

DOWN key

8

Digital indicator (Red)

9

PRO indicator (Yellow)

5

Mounting

When mounting this product, use M3 screws (prepare separately).
Use a tightening torque of 0.5 N m for mounting.

37m

m

18mm

M3 screws

Mounting hole dimensions

Mounting direction

 

When performing measurements of moving objects with excessively 

different materials and colors, mount the product in the following direc-

tions to minimize measurement errors. 

 

When performing measurements of rotating objects, mount the prod-

uct as follows. The effect of up/down deflection and position deviation 

can be minimized by mounting the sensor in the correct direction.

 

When there is a step in the moving object, mount the product as fol-

lows. The effect of reflection deviation by the edges of the steps can 

be minimized by mounting the sensor in the correct direction.  

Summary of Contents for HG-C1030

Page 1: ...formance standards for light emitting products These standards classify laser products according to their level of hazard and provide safety measures for the respective classes Warning label and position LASER RADIATION LASER APERTURE CLASS2 LASER PRODUCT IEC60825 1 2007 MAXIMUM OUTPUT 1mW PULSE DURATION 5ms max WAVELENGTH 655nm DO NOT STARE INTO BEAM An English warning label is attached to this p...

Page 2: ... ground AGND External input Analog input device 7 Teaching 2 point teaching This method is the basic teaching method 1 2 Distance Background Sensing object Threshold ON OFF 1 Press the TEACH key when the back ground is present 2 Press the TEACH key when the sensing object is present Stable sensing is possible Stable sensing is not possible Limit teaching This teaching method is recommended if smal...

Page 3: ...2_SL 1st time Threshold 1_SL Threshold surface ON OFF OFF 1 Press the TEACH key when the sensing object P 1 is present 1st time 2 Press the TEACH key when the sensing object P 2 is present second time Stable sensing is possible Stable sensing is not possible 3 point teaching window comparator mode This is the method to perform 3 point teaching P 1 P 2 P 3 and to set the threshold range by setting ...

Page 4: ...the TEACH key for 1 second Automatic Press the TEACH key 1 second Change the threshold value Measurement display When performing a fine adjustment of the threshold of or press the UP key or DOWN key After or is displayed the fine adjustment of the threshold can be performed Confirmed Automatic automatically set after 3 seconds Press the TEACH key Press the UP DOWN key Press the UP DOWN key or 9 Pe...

Page 5: ...MODE is active To re turn to the measurement display press the DOWN key again for 3 seconds or more Setting Default setting Description Response speed Set the response time High precision 10ms Standard 5ms High speed 1 5ms Output operation Select the control output operation mode Light ON Dark ON Sensing output Set the sensing output Normal sensing mode 1 point teaching Window comparator mode 2 po...

Page 6: ...e sensing distance is within the specification range Set the display to any setting except Offset During teaching the measurement is not performed normally Confirm that the sensing distance is within the specification range System error Please contact our office 14 Cautions This product has been developed produced for industrial use only Make sure that the power supply is OFF before starting the w...

Page 7: ... 4 to 5V Alarm 0mA Load impedance max 250Ω Response time Switchable between high speed 1 5ms standard 5ms and high precision 10ms External input NPN output type NPN non contact input Input conditions Invalid 8 to V DC or open Valid 0 to 1 2VDC Input impedance 10kΩ PNP output type PNP non contact input Input conditions Invalid 0 to 0 6V DC or open Valid 4 to V DC Input impedance 10kΩ Degree of prot...