1

INSTRUCTION MANUAL

Micro Laser Distance Sensor for IO-Link (CMOS)

ME-HGC1000LV1EN 09/2018

Thank you very much for purchasing Panasonic products. Please read this 

Instruction Manual carefully and thoroughly for the correct and optimum 

use of this product. Kindly keep this manual in a convenient place for quick 

reference.

WARNING

 

This product is intended to detect objects. Do not use it to carry out 

safety control functions to prevent accidents.

 

Never use this product as a sensing device for personnel protection.

 

Do not look into the beam directly during operation.

1

CE marking

This product complies with the following standards and 

regulations.

 

For the EU: EMC Directive 2014/30/EC 

Contact for CE: 

Panasonic Marketing Europe GmbH 

Panasonic Testing Center 

Winsbergring 15, 22525 Hamburg, Germany 

2

Confirmation of packed content

 

Sensor

1pc.

 

Laser warning label (JIS Standards, GB Standard)

1 set each

 

● FDA certification label

1pc.

 

Instruction Manual (Japanese, English)

1pc. per 

language

3

Safe use of laser product

In order to prevent accidents caused by laser products and to protect the 

users, IEC, JIS and FDA established the following standards:   

IEC: 

IEC 60825-1-2014 (EN 60825-1-2014) 

JIS: 

JIS C 6802-2014 

FDA: 

PART 1040 (Performance standards for light-emitting products)

These standards classify laser products according to their level of hazard 

and provide safety measures for the respective classes.

Warning label and position

LASER  RADIATION

LASER  APERTURE

CLASS2 LASER PRODUCT

(IEC60825-1 2007)

(MAXIMUM OUTPUT) 1mW

(PULSE DURATION) 5ms max. 

(WAVELENGTH) 655nm

DO NOT STARE

INTO BEAM

An English warning label is attached to this product.

4

Part description

5

6

7

8

9

1

2

3

4

No.

Item

1

Zero set indicator (Yellow)

Lights when the zero set function is 

enabled.

2

Teaching indicator (Yellow). Lights when teaching is in process

3

Output operation indicator 

(Orange)

Lights when the output is on

4

Laser emission indicator 

(Green)

Lights when the laser beam is ON

5

TEACH key

6

UP key

7

DOWN key

8

Digital indicator (Red)

9

PRO indicator (Yellow)

Lights in Pro mode
Flashes in normal status during IO-Link 

communication
OFF in normal status without IO-Link 

communication

5

Mounting

 

When mounting this product, use M3 screws (prepare separately). 

Use a tightening torque of 0.5 N m for mounting.

 

When mounting this product using the sensor mounting bracket (op-

tional), also use a tightening torque of 0.5N·m

37m

m

18mm

M3 screws

Mounting hole dimensions

If the fixed ring loosens, the connector will come off, causing this product to gen

-

erate a communication error. Before use, check that the fixed ring is not loose

.

 

 

Firmly tighten the fixed ring by rotating it.

Fixed ring

Mounting direction

 

● When performing measurements of moving objects with excessively 

different materials and colors, mount the product in the following direc

-

tions to minimize measurement errors. 

 

When performing measurements of rotating objects, mount the prod-

uct as follows. The effect of up/down deflection and position deviation 

can be minimized by mounting the sensor in the correct direction.

HG-C1000L 

Series

Summary of Contents for HG-C1000L Series

Page 1: ...ER RADIATION LASER APERTURE CLASS2 LASER PRODUCT IEC60825 1 2007 MAXIMUM OUTPUT 1mW PULSE DURATION 5ms max WAVELENGTH 655nm DO NOT STARE INTO BEAM An English warning label is attached to this product 4 Part description 5 6 7 8 9 1 2 3 4 No Item 1 Zero set indicator Yellow Lights when the zero set function is enabled 2 Teaching indicator Yellow Lights when teaching is in process 3 Output operation ...

Page 2: ...tom hold function Setting Index84 Release Index2 Zero set function Save in nonvolatile memory Index2 Execute Index2 Release of nonvolatile memory Index2 Key lock function Setting Release Index12 Response Speed Setting 10ms 5ms 1 5ms Index66 Output operation setting Light ON Dark ON Index61_1 Hysteresis setting Hysteresis value Index61_3 Shift setting Mode Index74_1 Shift amount setting Shift amoun...

Page 3: ... a 1 point teaching This mode is used for sensing within the threshold range When performing the 1 point teaching window comparator mode preset Window comparator mode 1 in the sensing output setting of the PRO mode For the setting method refer to section 13 PRO mode setting ON OFF OFF Sensing object Threshold 2_SL Reference surface Threshold 1_SL 1 Press the TEACH key twice when the sensing object...

Page 4: ...nges in the measured values and to only detect sudden changes To use the Rising differential mode or Trailing differential mode preset Ris ing differential mode oder Trailing differential mode in the sensing output setting of the PRO mode For the setting method refer to section 13 PRO mode setting The threshold can be set by using the threshold value fine adjustment func tion see section 9 Thresho...

Page 5: ...set setting Confirmed Press the UP and DOWN key simultaneously for 3 seconds Zero set release Automatic will be displayed during this period Press the UP and DOWN key simultaneously for 6 seconds 12 Key lock function The key lock function is to prevent acceptance of key operations so that the conditions in each setting mode are not changed accidentally When the key operation is performed after the...

Page 6: ...ms 50ms 100ms 250ms 500ms 1 000ms 5 000ms Display The display of the measured value can be changed Normal Invert Offset Hold Set the control output and the analogue output operation when a measurement error occurs insufficient light intensity saturation of light intensity out of measurement range Hold OFF Hold ON ECO The digital display can be set to go OFF when key operation is not performed for ...

Page 7: ...ulator ensure that the frame ground F G terminal of the power supply is connected to an actual ground If noise generating devices switching regulators inverter motors etc are used around the sensor mounting area make sure to connect the frame ground FG terminal of the device Do not use this product during the transient state when the power sup ply is turned ON The overall length of the cable can b...

Page 8: ...urce current Leakage current max 0 1mA Output operation Selectable either Light ON or Dark ON Short circuit protection Incorporated auto reset Response time Switchable between high speed 1 5ms standard 5ms and high precision 10ms IO Link communication IO Link specification Ver1 1 Baud rate COM3 230 4kbps Process data length 4byte Degree of protection IP67 IEC Degree of pollution 2 Ambient temperat...