18
6.1.
Built-in Memory Self Check Execution (HDC-TM700 only)
Touch the [ 3 ] of LCD, select Built-in memory self check execution.
Operation specifications
Indication contents
• Built-in memory self check result display
Display the Built-in memory self check execution.
Displays other than “OK” are abnormalities of Built-in memory.
Push the “Menu” button to end the service mode, and then POWER OFF.
6.2.
Lock Search History Indication
Touch the [ 4 ] of LCD, select Lock search history indication.
Operation specifications
Indication contents
• Lock search history indication
Display the camera system error cord for three histories saved in EEPROM.
• The error cord contents which are displayed
Push the “Menu” button to end the service mode, and then POWER OFF.
Error code
Function
51
Focus control is abnormal
52
Zoom control is abnormal
53
OIS lens control is abnormal
71
Lens cover open/close is abnormal
72
Cooling fan is abnormal
73
High temperature is abnormal
33
Communication between camera to ARM is abnormal
Summary of Contents for HDC-SD700EB
Page 10: ...10 3 5 Formatting ...
Page 11: ...11 4 Specifications ...
Page 12: ...12 ...
Page 13: ...13 ...
Page 25: ...25 Fig D2 8 3 2 Removal of the ESD P C B Unit Fig D3 ...
Page 26: ...26 8 3 3 Removal of the Cover Board Unit Fig D4 8 3 4 Removal of the Top Case Unit Fig D5 ...
Page 27: ...27 Fig D6 8 3 5 Removal of the Front Unit Fig D7 ...
Page 32: ...32 Fig D20 Fig D21 ...
Page 35: ...35 Fig D28 8 3 19 Removal of the EVF Unit Fig D29 8 3 20 Removal of the Top Frame Fig D30 ...
Page 41: ...41 Fig D47 8 3 35 Removal of the Focus Guide Pole L and Focus Guide Pole S Fig D48 ...
Page 80: ...S 35 S7 3 EVF Section B23 59 B22 58 60 61 62 63 65 64 66 67 68 69 70 72 71 73 74 75 76 77 B24 ...
Page 81: ...S 36 S7 4 LCD Section 27 28 29 26 30 32 23 31 25 22 B7 B8 24 ...