18
6.1.
Lock Search History Indication
Touch the [ 4 ] of LCD, select Lock search history indication.
Operation specifications
Indication contents
• Lock search history indication
Display the camera system error cord for three histories saved in EEPROM.
• The error cord contents which are displayed
Push the “Menu” button to end the service mode, and then POWER OFF.
6.2.
Power ON Self Check Result Display
Touch the [ 5 ] of LCD, select Power ON self check result display.
Operation specifications
Indication contents
• Power ON self check result display
Function to diagnose correct function of the device and interface between devices result display.
Display the following commnucation test result.
- CAM-PWR : Commnucation test between IC2006 to IC301
- CAM-UNI : Commnucation test between IC3401 to IC301
Display other than “OK” are abnomalities of each lines.
Cutting of battery connection or AC power supply connection to end the service mode.
Error code
Function
51
Focus control is abnormal
52
Zoom control is abnormal
53
OIS lens control is abnormal
71
Lens cover open/close is abnormal
72
Cooling fan is abnormal
73
High temperature is abnormal
33
Communication between camera to ARM is abnormal
Summary of Contents for HDC-SD600EB
Page 10: ...10 3 5 Formatting ...
Page 11: ...11 4 Specifications ...
Page 12: ...12 ...
Page 13: ...13 ...
Page 23: ...23 Fig D2 8 3 2 Removal of the Cover Board Unit Fig D3 ...
Page 24: ...24 8 3 3 Removal of the Top Case Unit Fig D4 Fig D5 8 3 4 Removal of the Front Unit Fig D6 ...
Page 25: ...25 Fig D7 8 3 5 Removal of the Side Case R Unit Fig D8 ...
Page 29: ...29 8 3 13 Removal of the Monitor P C B Unit Fig D19 Fig D20 ...
Page 34: ...34 8 3 24 Removal of the IRIS Unit Fig D35 8 3 25 Removal of the Zoom Motor Fig D36 ...
Page 37: ...37 8 3 31 Removal of the Focus Guide Pole L and Focus Guide Pole S Fig D43 ...
Page 61: ...S 20 ...
Page 72: ...S 31 S7 3 LCD Section 51 54 55 56 57 8 58 B54 B55 53 52 50 40 ...