7 Service Fixture & Tools
7.1 When Replacing the Main P.C.B.
After replacing the MAIN P.C.B., be sure to achieve adjustment.
7.2 Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
7.2.1 Extention Cable Connection
No.
Parts No.
Connection
Form
1 RFKZ0354
FP6001(MAIN) - MONITOR FPC
37PIN 0.3 FFC
1 RFKZ0354
FP201(MAIN) - MONITOR FPC (HC-WX970/WX979/WX970M only) 37PIN 0.3 FFC
2 VFK1581A6025 PP6001(MAIN) - PS6401(SD HOLDER)
60PIN 0.5 B to B
3 VFK1388
FP6012(MAIN) - FRONT FFC
12PIN 0.5 FFC
4 VFK1440
FP4803(SD HOLDER) - TOP CASE UNIT
10PIN 0.5 FFC
Page 1 of 2
1/3/2018
file://C:\Users\sh.dehghani\AppData\Local\Temp\Rar$EXa0.510\viewing\SGML_VIEW_D...